Gas Connection - Waldorf RNB8110GE Installation And Operation Manual

Gas target top range electric ovens
Table of Contents

Advertisement

- All Other Markets:
Input Rate (N.H.G.C.)
Gas Supply Pressure
Burner Operating Pressure (*)

Gas Connection

Input Rate (N.H.G.C.)
Gas Supply Pressure
Burner Operating Pressure (*)
Gas Connection
NOTE:

(**) Measure burner operating pressure at target top hob manifold test point with target
top burner (Inner and outer ring) operating at full setting.

NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.

TOWN GAS Only - Burner operating pressure is to be adjusted using adjustable gas
regulator supplied. Town Gas Option is only available with specific ex-factory built
Town Gas models, which can also be converted to any other gas. Standard models can
only be converted between Nat. Gas, LP Gas and Butane, but not Town Gas.

Refer to 'Gas Conversion and Specifications' section of this manual for further
details.
Gas Connection
Gas supply connection point is located at rear of the appliance, 130mm from right hand side, 32mm
from rear, 655mm from floor and is reached from beneath appliance. An optional underside connec-
tion is available. (Refer to the 'Dimensions' section).
Connection is ¾" BSP male thread.
Natural Gas
45 MJ/hr
1.13 - 3.40 kPa
0.95 kPa
3
/
" B.S.P. Male
4
LP Gas (Propane)
45 MJ/hr
2.75 - 4.50 kPa
2.60 kPa
3
/
" B.S.P. Male
4
5
Specifications
Town Gas (**)
45 MJ/hr
0.75 - 1.50 kPa
0.63 kPa
Butane
45 MJ/hr
2.75 - 4.50 kPa
2.60 kPa

Advertisement