2.
Slide the WEIGH BIN into position.
hinged access window.
If bin is already in place, remove any shipping materials, packing
tape or string.
3.
Hang the Color and Additive Feeders:
a. Lift side latches and fully extend slide assembly.
hopper.
Leave slide extended.
b. Tilting the entire slide assembly, motor end up, insert one
corner of hanger cross bar behind frame corner post.
c. Rotate assembly into place so both ends of cross bar are behind
corner posts.
d. Lower into place, bottom edge resting on frame and cross bar
properly positioned behind corner posts.
e. Re-install hopper.
4.
Place the controller on the support tray and plug in all cords:
a. Air solenoid 8 or 14 pin plug into the matching receptacle.
b. Auger feeder drive motors into duplex receptacle.
c. Mixer motor into right side of controller.
d. Sensor cord plug into right side of controller.
e. Load Cell plug into port on left side of controller.
5.
Plug the CONTROLLER into the receptacle located under the
controller tray.
IMPORTANT:
Do NOT plug the controller into a separate power
source.
the blender frame ground path.
controller located in a remote location, MAKE CERTAIN
that the power to the controller comes from the
receptacle mounted on the Blender frame.
6.
Plug the power cord coming from this box into a 110 volt power
source (220 volt outside U.S.).
power source for the entire system, including the controller.
See: WIRING CONSIDERATIONS, next page.
require a 240 volt power source for the mix motors.
7.
Connect air pressure to the unit.
recommended (40 psi for the Micro Blender).
recommended.
NOTE:
GBM Micro Blenders should be set to 40 psi (2.7 bar).
The Vertical Valves used in removable hoppers on Micro
Blenders, 100, and 200 series blenders are more accurate at
the lower 40 psi pressure setting.
8.
Remove all protective paper from the plastic windows.
It rests behind the clear
Install with the air cylinder toward you.
Slide motor forward until latches engage.
The controller ground path MUST be the same as
This cord MUST provide the ONLY
About 80 psi (5.5 bar) is
Page 9
Remove the
If your system has the
1800 series blenders also
Lubricated air is NOT