Conair GB User Manual page 105

Gb and wsb series gravimetric blenders with 12-component control
Hide thumbs Also See for GB:
Table of Contents

Advertisement

SPECIFICATIONS
FEEDER LOCATIONS
D
C
4
C
2
1
3
A
B
B
TOP VIEW GB1840
CONTROL
D
E
F
MODELS
Performance characteristics
Batch size lbs {g}
Maximum throughput lbs/hr {kg/hr}*
Bin Capacity - Main Ingredient ft
Bin Capacity - Minor Capacity ft
Maximum number of materials
Number of discharge valves
Number of additive feeders
Control software (# of components)
Dimensions inches {mm}
A - Height above mounting plate
B - Width †
C - Depth †
D - Controller height
E - Controller width
F - Controller depth
Weight lbs {kg}
Installed
Shipping
Voltage Running load amps‡
110V/1 phase/60hz (control)
220V/1 phase/60hz (mixer)
220V/1 phase/60hz (control)
220V/1 phase/60hz (mixer)
220V/1 phase/50hz (control)
220V/3 phase/50hz (mixer)
400V/3 phase/50hz (mixer)
Compressed air requirements
Discharge valves
Maximum loader sizes §
Number of 20 inch loaders
Number of 15 inch loaders
One Conair Drive
Pittsburgh, PA 15202
B
A
FRONT VIEW
GB1840/GB1860
GB1840
39.7 {18000}
39.7 {18000}
4114 {1870}
2566 {1166}
3
{liter}
6.7 {189.7}
3
{liter}
3.8 {107.6}
8
4
up to 4
4 or 12
93 {2362.2}
56 {1421.4}
34 {863.6}
11.25 {285.75}
11.25 {285.75}
12.25 {311.15}
12.25 {311.15}
8.19 {208.03}
8.19 {208.03}
730 {331}
850 {385.5}
0.3
8.2
0.2
8.2
0.2
4.4
2.2
80 psi @ 0.2 ft
3
/min {5.5 bars @ 0.09 liters/sec}
1/4 in. NPT fitting
2
4
412-312-6000
GRAVIMETRIC BATCH BLENDERS
AutoWeigh GB1840 and 1860 Models
FEEDER LOCATIONS
C
D
C
A
TOP VIEW GB1860
SIDE VIEW
GB1840
GB1860
MOUNTING INTERFACE
3.8 {107.6}
3.8 {107.6}
10
6
up to 4
12
93 {2362.2}
56 {1421.4}
34 {863.6}
SPECIFICATION NOTES
* Maximum throughput rates are based on 35 lb/ft
letized material and using all dispense valves. Use of
730 {331}
feeders for minor ingredients will reduce this rate.
850 {385.5}
Refer to the selection guide for more specific through-
put information.
0.3
† Feeders will increase width dimensions. Please refer
8.2
to feeder specification.
0.2
‡ Each auger feeder requires an additional 1 amp @
8.2
120V or 0.5 amp @ 240V.
0.2
4.4
§ Maximum loader sizes may be used only when
2.2
the loader is adjacent to loaders of a smaller
diameter.
3
6
FAX 412-312-6227
www.conairnet.com
C
8
4
7
2
3
1
B
B
NOTE: Any one of the
feeders (A,B,C or D)
can be designated
position 5 or 6.
(4) 9/16 in. {14.3 mm}
IB04
diameter bolt holes
4 in. {101.6 mm}
8 in. {203.2 mm}
diameter
square bolt pattern
through hole
14.5 in.
{368.3 mm}
15 in. {381 mm}
20 in. {508 mm}
APPENDIX B
TPS014/1199
C
SIDE VIEW
GB1860
16 in.
{406.4 mm}
3
pel-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents