Keypad - Summary Description; Manual Mode - Conair GB User Manual

Gb and wsb series gravimetric blenders with 12-component control
Hide thumbs Also See for GB:
Table of Contents

Advertisement

Detailed explanations are given on the pages that follow.
AUTOMATIC OPERATION MODE:
VIEW:
View Data: date, time, cycles, and each component weight.
Press VIEW,* to print data.
RCP:
Enter and retrieve stored RECIPES.
BTCH:
View BATCH data: Target Weight, Current Portion, Accumulated
Total, and Batch Count.
FAST:
Run rapid FAST cycles after a normal weighed cycle.
TAG:
Tag Work Order and Operator numbers to all reports.
EXIT:
Press to EXIT all sequences from ALL MODES.
SET:
Press to review or change settings.
CE:
Press to display "raw signal" weight readout for 3 seconds.

MANUAL MODE:

Press: "*"; then (11111) or your own 5 digit password.
OPER:
Operate all devices manually; open and close valves.
TIME:
Operate devices for a selected time period.
CAL:
Operate devices to learn rate.
Above keys use 1 through 9, A, B, C, DUMP, MIX, HOLD, ALARM.
ZERO:
Zero the tare weight with the bin empty.
FULL:
Using known weights, enter gram weight to calibrate load cells.
*00
Clear DATA fields.
*99
Set flag to enable weight calibration of load cells.
PROGRAM MODE:
Press: "*"; then (22222) or your own password.
SET:
Enter settings if access in Automatic mode has been locked out.
PARA:
View or change system parameters.
"*" for previous, SET for next table, VIEW for previous table.
STAR FUNCTIONS: Press * and two numbers for the following functions:
*02
Extrusion and Yield Control.
*03
Four digit (xx.xx) settings.
*04
Simulate FOUR software.
*05
Inhibit table clearing.
*11
DATE - TIME, real-time clock.
*12
Move table from ROM to RAM.
*23
Move from RAM to EEPROM.
*32
Move from EEPROM to RAM.
*14
Set types: REG, NAT, ADD, OFF.
*25
ROM OK flag, "CE" to clear.
*33
Special Alarms.
*44
End cycle - bin full.
*45
Change MANUAL mode password.
*47
Totalizer flag.
*48
Dispense range xx.x to xxx.
Use "*" key to select readout or toggle flags ON or OFF.

KEYPAD - SUMMARY DESCRIPTION

(normal operation on power up)
CE = clear displayed field.
Page 29
Press PARA for next in list,
*52
Double dump weigh bin.
*54
Print cycle information.
*66
GB/WSB I.D. number (1-255).
*69
Regrind as second natural.
*71
Color percent of blend.
*72
Additive percent of blend.
*74
Stop, alarm MAX wt exceeded.
*75
Alarm on weight drop.
*77
Print parameters.
*78
Change program mode PASSWORD.
*82
Precision Ratioing.
*87
VOLUMETRIC operation.
*88
Print display readout.
*89
Select pounds, kilos.
*98
Display raw weight number.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents