Indoor Unit Wiring - EAS Electric EFMV2 Series Instruction Manual

Floor-ceiling air conditioning unit
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 35
NOTE: When connecting the wires,
strictly follow the wiring diagram
found inside the electrical box cover.
2. Remove the electric cover of the out-
door unit. If there is no cover on the
outdoor unit, take off the bolts from
the maintenance board and remove
the protection board.
3. Connect the u-lugs to the terminals. Match
the wire colors/labels with the labels on the
terminal block. Firmly screw the u-lug of each
wire to its corresponding terminal.
4.
Clamp down the cable with the cable clamp.
Insulate unused wires with electrical tape.
5.
Keep them away from any electrical or
metal parts.
6. Reinstall the cover of the electric con-
trol box.

Indoor Unit Wiring

1. Prepare the cable for connection
a. Using wire strippers, strip the rubber
jacket from both ends of the signal
cable to reveal about 15cm (5.9") of
the wire.
b. Strip the insulation from the ends of
the wires.
c. Using a wire crimper, crimp the u-
lugs to the ends of the wires.
2. Open the front panel of the indoor unit.
Using a screwdriver,remove the cover of
the electric control box on your indoor
unit.
3. Thread the power cable and the signal
cable through the wire outlet.
4. Connect the u-lugs to the terminals.
Match the wire colors/labels with the
labels on the terminal block. Firmly
screw the u-lug of each wire to its
corresponding terminal. Refer to the
Serial Number and Wiring Diagram
located on the cover of the electric
control box.
Cover
Screw
32
wire outlet
control box
Wiring diagram
Connective wiring diagram
Magnetic ring
(if supplied and packed with
the accessories)
1 2 3
CAUTION
While connecting the wires, please
strictly follow the wiring diagram.
The refrigerant circuit can become
very hot. Keep the interconnection
cable away from the copper tube.
5. Clamp down the cable with the cable
clamp. The cable must not be loose or
pull on the u-lugs.
6. Reattach the electric box cover.
Pass the belt through
the hole of the
Magnetic ring to fix it
on the cable
V.1

Advertisement

Table of Contents
loading

Table of Contents