Install Drain Joint; Anchor Outdoor Unit - EAS Electric EFMV2 Series Instruction Manual

Floor-ceiling air conditioning unit
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 35
Step 2: Install drain joint (Heat pump unit
only)
Before bolting the outdoor unit in place,
you must install the drain joint at the
bottom of the unit. Note that there are
two different types of drain joints depen-
ding on the type of outdoor unit.
If the drain joint comes with a rubber seal
(see Fig. A ), do the following:
Fit the rubber seal on the end of the
1.
drain joint that will connect to the
outdoor unit.
Insert the drain joint into the hole in
2.
the base pan of the unit.
Rotate the drain joint 90° until it clicks
3.
in place facing the front of the unit.
Connect a drain hose extension (not
4.
included) to the drain joint to redirect
water from the unit during heating
mode.
If the drain joint doesn't come with a
rubber seal (see Fig. B ), do the following:
Insert the drain joint into the hole in
1.
the base pan of the unit. The drain
joint will click in place.
Connect a drain hose extension (not
2.
included) to the drain joint to redirect
water from the unit during heating
mode.
Seal
Drain joint
(A)
IN COLD CLIMATES
In cold climates, make sure that the
drain hose is as vertical as possible to
ensure swift water drainage. If water
drains too slowly, it can freeze in the
hose and flood the unit.
Base pan
hole of
outdoor unit
Seal
(B)
Step 3: Anchor outdoor unit
The outdoor unit can be anchored
to the ground or to a wall-mounted
bracket with bolt(M10). Prepare the
installation base of the unit accor-
ding to the dimensions below.
UNIT MOUNTING DIMENSIONS
The following is a list of different
outdoor unit sizes and the distan-
ce between their mounting feet.
Prepare the installation base of
the unit according to the dimen-
sions below.
Outdoor Unit Types and Specifica-
tions
Split Type Outdoor Unit
D
25
H
W
W
H
A
V.1
B

Advertisement

Table of Contents
loading

Table of Contents