Outdoor Unit Wiring; Indoor Unit Wiring - EAS Electric EDMV2 Series Instruction Manual

Duct-type air conditioning
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 41

Outdoor Unit Wiring

WARNING
Before performing any electrical or
wiring work, turn off the main
power to the system.
1. Prepare the cable for connection
a. You must first choose the right
cable size. Be sure to use H07RN-
F cables.
NOTE: In North America, choose the
cable type according to the local
electrical codes and regulations.
Minimum Cross-Sectional Area of Power
and Signal Cables (For reference)
Nominal Cross-Sectional
Rated Current of
Appliance (A)
> 3 and ≤ 6
> 6 and ≤ 10
> 10 and ≤ 16
> 16 and ≤ 25
> 25 and ≤ 32
> 32 and ≤ 40
CHOOSE THE RIGHT CABLE SIZE
The size of the power supply cable,
signal cable, fuse, and switch needed is
determined by the maximum current
of the unit. The maximum current is
indicated on the nameplate located on
the side panel of the unit. Refer to this
nameplate to choose the right cable,
fuse, or switch.
NOTE: In North America, please choose
the right cable size according to the
Minimum Circuit Ampacity indicated
on the nameplate of the unit.
b.
Using wire strippers, strip the
rubber jacket from both ends of the
signal cable to reveal approxima-
tely 15cm (5.9") of wire.
c. Strip the insulation from the ends.
d.
Using a wire crimper, crimp u-
lugs on the ends.
NOTE: When connecting the wires,
strictly follow the wiring diagram
found inside the electrical box cover.
Area (mm²)
0.75
1
1.5
2.5
4
6
2. Remove the electric cover of the out-
door unit. If there is no cover on the
outdoor unit, take off the bolts from
the maintenance board and remove
the protection board.
3. Connect the u-lugs to the terminals. Match
the wire colors/labels with the labels on the
terminal block. Firmly screw the u-lug of each
wire to its corresponding terminal.
4.
Clamp down the cable with the cable clamp.
Insulate unused wires with electrical tape.
5.
Keep them away from any electrical or
metal parts.
6. Reinstall the cover of the electric con-
trol box.

Indoor Unit Wiring

1. Prepare the cable for connection.
a.
Using wire strippers, strip the rubber ja-
cket from both ends of the signal cable
to reveal about 15cm (5.9") of the wire.
Strip the insulation from the ends of the
b.
wires.
c. Using a wire crimper, crimp the u-lugs
to the ends of the wires.
2. Remove the cover of the electric
control box on your indoor unit.
3. Connect the u-lugs to the terminals.
Match the wire colors/labels with the
labels on the terminal block. Firmly
screw the lug of each wire to its
corresponding terminal. Refer to the
Serial Number and Wiring Diagram
located on the cover of the electric
control box.
Control box
Wiring diagram
33
Cover
Screw
Connective wiring diagram
V.2

Advertisement

Table of Contents
loading

Table of Contents