MAINTENANCE
4.7.1

ENGINE AIR CLEANER MAINTENANCE

NOTICE
Before servicing the filter elements clean dust cups of the
pre-cleaners.
Servicing the main filter elements, illust. Z24050:
Never service air cleaner while engine is running.
Clean main filter elements when the fault message "Air
cleaner element restricted" is displayed on the ETM screen
or when the service indicator (8) at the air outlet pipe connec-
tion shows a red signal. Replace elements after 3 cleanings
or annually, whichever occurs first.
1. Remove elements in sequence of reference numbers (1 to 4).
2. Clean and check respectively. replace main filter element.
Wipe out filter housing with a clean cloth.
3. Element cleaning methods:
Clean main element by one of the following methods.
Compressed air or washing:
Compressed air is recommended when element will be re-
used immediately because a washed element must be dried
before re-use.
Compressed air:
Direct air through element in the direction opposite to normal air
flow through the element. Move nozzle up and down while rotat-
ing element. Keep nozzle at least one inch from pleated paper.
Maximum air pressure to prevent damage of element is 100 P.S.I.
(6 bar).
Washing:
1. Soak element 15 minutes or more in cleaning solution. See
package for full instructions.
2. Rinse until water is clear maximum water pressure 40 P.S.I.
(2.5 bar).
3. Air-dry or use warm flowing air, max. 160° F (+70° C). Do not
use compressed air or light bulbs.
REMARK
Before installing main elements (4) check service indicator (6)
of safety element (7). If a red signal is shown, replace safety ele-
ment (7). Clean indicator (6) then suck on the outer side of the
indicator to reset signal to green indication.
4. Install main filter elements (4).
CAUTION
4.7 WHEN NECESSARY
269