OPERATION

3.17.1 OPERATION OF THE AUTOMATIC LUBRICATION SYSTEMS

The shovel is equipped with two automatic lubrication systems:
1. Central Lubrication System (CLS) for lubrication of the attach-
ment bearings, the slewing connection bearing and the slew
gear bearing.
2. Slew ring gear pinion Lubrication System (SLS) for lubrication
of the slew ring teeth.
These systems work automatically as soon as the engine is run-
ning at high idle speed. The slew ring gear lubrication system is
only activated during slewing movement of the superstructure.
The ETM System monitors the function of both lubrication sys-
tems. Trouble conditions of the lubrication systems are indicated
through fault messages on the ETM display.
Legend for illustration Z 23096
Electrical components of the Central Lubrication System (CLS) located on the X2 switch
board in the cab base
D3
Pause time relay, factory setting 60 minutes
D4
Monitoring time relay, factory setting 3 minutes
D39
Time relay for switching off the bucket motion if the lubrication system fails to function over a period
longer than 4.2 hours
K28
Relay initiates a fault message if power supply to the lubrication system is interrupted
K30
Relay initiates a fault message if the lubrication cycle is not carried out in the adjusted time period
K136
Relay initiates a fault message if the grease barrel is empty
Electrical components of the Slew ring gear Lubrication System (SLS)
D7
Pause time relay, factory setting 9 minutes
D8
Monitoring time relay, factory setting 2 minutes
D40
Time relay for switching off the bucket motion if the lubrication system fails to function over a period
longer than 4.2 hours
K35
Relay initiates a fault message if power supply to the lubrication system is interrupted
K37
Relay activates the slew ring gear lubrication system during slewing of the superstructure
K38
Relay initiates a fault message if the lubrication cycle is not carried out in the adjusted time period
K138
Relay initiates a fault message if the grease barrel is empty
B43
Line pressure switch of CLS interrupts lubrication cycle
B46
Line pressure switch of SLS interrupts lubrication cycle
S24
Rotary switch for manual actuation of the CLS
S26
Rotary switch for manual actuation of the SLS
3.17 AUTOMATIC LUBRICATION SYSTEMS