Swing Gear And Motor Adapter Housing - Change Oil - Komatsu 06253 Operation & Maintenance Manual

Hydraulic mining shovel
Table of Contents

Advertisement

MAINTENANCE

4.14.1 SWING GEAR AND MOTOR ADAPTER HOUSING - CHANGE OIL

REMARK
The machine can be equipped either with a swing gear of
manufacturer "L&S" or of manufacturer "Siebenhaar". Refer to the
data plate on the swing gear housing to find out the manufacturer
of the swing gear.
Swing gear manufactured by "L&S"
Legend for illustration Z22913
Swing gear
(A)
Position of oil level gauge for checking the oil levels
(1)
Oil level gauge
(2)
Oil filler plug
(3)
Breather filter
(7)
Drain coupling or evacuation nozzle for Wiggins system
Motor Adapter Housing
(4)
Oil level gauge and filler opening. This opening can also be used for connecting a
suction pump when changing the oil.
(5)
Breather filter
(6)
Oil drain plug
Swing Gear, change oil:
1. Use adequate working platform for draining the oil. Place
receptacles of sufficient capacity (approx. 60 liter) below drain
couplings (7). Attach drain hose (part of tool set) to drain cou-
pling (7). Remove parts (1, 2 and 3) to speed up draining. On
swing gears with evacuation nozzle (7), use the Wiggins sys-
tem for changing the oil.
2. Clean breather filter (3) with compressed air from inside to
outside and re-install.
3. After the oil is completely drained, flush the gear with the reg-
ular gear oil.
4. Remove drain hose from coupling (7) and attach the protec-
tion cap onto the drain coupling.
5. Fill gear housing through filler opening (2) up to the "MAX"
mark on level gauge (1) with fresh oil and re-install plug (2).
NOTICE
For checking the oil level insert the level gauge (1) but
DO NOT screw in, see detail (A).
6. After short operating period check oil level and housing for
leaks.
4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR