Roland EGX-600 Service Notes page 61

Hide thumbs Also See for EGX-600:
Table of Contents

Advertisement

3 Replacement of Main Parts
<Y Axis Load Check>
Turn on the Power while pressing the [
13
keys too enter the Service Mode.
Select the [LOAD] menu by pressing the [MENU] key and
press [ENTER] key.
3
Select the [AXIS Y] in the [LOAD] menu and press [ENTER]
14
key. Then, Carriage moves to the Limit Position.
Enter the value 500 and press the [ENTER] key.
After setting the value, the load check starts.
15
The Carriage moves in the Y direction to check the load.
If the check is OK, fix the Covers.
If the check is NG, repeat 6 to 13 .
58
], [
], [
]
[ ], [ ], [ ] + POWER ON
[MENU] key
CHECK MODE
LOAD
CON.
CARD
[ENTER] key
AXIS
X Y Z S
[ENTER] key
AXIS
X Y Z S
VALUE 500
[ENTER] key
AXIS
X Y Z S
VALUE 500
OK