Roland EGX-600 Service Notes page 51

Hide thumbs Also See for EGX-600:
Table of Contents

Advertisement

3 Replacement of Main Parts
Tighten up the screws fixing the Carriage Unit.
12
3
Connect the INSULOCK TIEs and the Sponge as the figure.
13
Tighten up the Spindle Motor Cable Bush.
Be careful with the position of the Sponge.
It is necessary to put it beside the Cable Holder.
Connect the Z Motor Cable, Z Limit Cable and Spinle Motor
14
Cable to the XY Junction Board.
Then, fix the Limit Switch and the Junction Board Cover.
<Z Axis Load Check>
Turn on the Power while pressing the [
15
keys to enter the Service Mode.
Select the [LOAD] menu by pressing the [MENU] key and
press [ENTER] key.
48
Spindle Cable Bush
Sponge and
INSULOCK TIE
], [
], [
]
Screws
Carriage Unit
Cable
Holder
[ ], [ ], [ ] + POWER ON
[MENU] key
CHECK MODE
LOAD
CON.
CARD
[ENTER] key
INSULOCK
TIEs