Put through the X Motor Pulley to the Drive Belt.
7
Then, tighten up the Screws with the collar and the other
Screws temporarily to the Motor Flange.
Attach the Spring and tighten up the screws.
8
Connect the X Motor Cable to the XY Junction Board.
9
<X Axis Load Check>
Turn on the Power while pressing the [
10
keys to enter the Service Mode.
Select the [LOAD] menu by pressing the [MENU] key and
press [ENTER] key.
Drive Belt
Screws with the collar
Drive Belt
], [
], [
]
3 Replacement of Main Parts
Flange
Flange
XY Junction
Board
X Motor Cable
[ ], [ ], [ ] + POWER ON
[MENU] key
CHECK MODE
LOAD
CON.
CARD
[ENTER] key
Screws
3
Spring