RJ12 pinout Input
pin1
input1
pin2
input2
pin3
input3
pin4
input4
pin5
gnd
pin6
input5
4.2. Configuration
Each of the digital inputs can be configured as a pulse meter, or as one of a number of predefined
sensors that can also be configured as alarms.
The possible configurable functions are:
Function
States
Pulse meter
N/A
Door alarm
Open/Closed
Bilge pump
On/Off
Bilge alarm
Ok/Alarm
Burglar alarm Ok/Alarm
Smoke alarm Ok/Alarm
Fire alarm
Ok/Alarm
CO2 alarm
Ok/Alarm
Generator
Running/Stopped
The function of each input can be configured in the GUI under Settings → I/O → Digital Inputs.
Venus GX (VGX) manual