Also the on/off/charger only switch in the CCGX will be disabled in the case.
In installation with a VE.Bus BMS, use the rocker switch instead - or add a Digital Multi Control to the
installation.
Minimum input current limit values
When PowerAssist is enabled in VEConfigure, there is a minimum input current limit. The actual limit
differs for each model.
After setting the input current to a value below the limit, it will automatically be increased again to
the limit.
Note that is still possible to set the input current limit to 0. When set to 0, the system will be in
passthrough (charger disabled).
Parallel and three phase systems
The configured AC input current limit is the total limit per phase.