Gas Supply Connection - Maytag Commercial MLE27PD Installation Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Leveling your dryer properly reduces excess noise and vibration.
1. Remove cardboard from beneath dryer. Place a level on top
edges of dryer, checking each side and front. If not level, tip
dryer and adjust legs up or down as shown in Steps 3 and 4,
repeating as necessary.
Not Level

GAS SUPPLY CONNECTION

GAS SUPPLY CONNECTION
Make Gas Connection
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
1. Remove red cap from gas pipe on back of dryer.
LEVEL
Not Level
2. Grip dryer from top and rock back and forth, making sure all four
feet are firmly on floor. Repeat, rocking dryer from side to side.
If dryer rocks, adjust leveling feet.
3. If dryer is not level, turn the leveling feet counterclockwise to
lower the dryer or clockwise to raise the dryer. Recheck levelness
of dryer and that all four feet are firmly in contact with the floor.
Repeat as needed.
HELPFUL TIP: You may want to prop up front of dryer about
4" (102 mm) with a wood block or similar object that will support
weight of dryer.
2. Connect gas supply to dryer. Use a pipe thread compound
approved for the type of gas supplied. If flexible metal tubing
is used, be certain there are no kinks.
If necessary for service, open the toe panel. Use a putty knife
to press on the toe panel locks located at the upper corners
of the toe panel. Pull downward on the toe panel to open.
Toe panel is hinged at the bottom.
3. Open the shut-off valve in the gas supply line and make sure
the dryer has its own gas supply opened.
4. Test all connections by brushing on an approved noncorrosive
leak-detection solution. Bubbles will show a leak. Correct any
leaks found.
LEVELING
LEVELING
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mlg27pd

Table of Contents