Gas Information - Maytag Commercial MLG45 Installation Manual

Stack dryer
Table of Contents

Advertisement

Available languages

Available languages

120 V Application with Neutral
Remove 3 screws holding down electrical box plate at the top
of the machine.
Remove 2 knockouts provided just in front of electrical box and
insert 3/4" UL listed strain relief into the holes.
Insert the wiring from the two 120 V 15 A circuits (one for top
tumbler and one for bottom tumbler) into the strain reliefs.
Determine the top pocket electrical connections by checking
wire label, which will be marked "top".
Connect wiring from 120 V 15 A circuit to top pocket wiring as
described in the following illustration (black to black, white to
white and green to chassis ground wire).
Connect wiring from 120 V 15 A circuit to remaining wires
(bottom pocket) as described in the following illustration (black
to black, white to white and green to chassis ground wire).
Tighten strain relief screws assuring to leave a 1/2" of slack in
box.
Replace electrical box plate by inserting 3 screws previously
removed.
Single-Phase Electrical Connection Leads
Black
+
Positive or L1
Neutral or L2
Input connection wiring must be sized properly to handle the
dryer's current draw. This information is printed on the dryer's
data label.
10
White
Green
+
+
Ground

Gas Information ________________

WARNING
Explosion Hazard
Use a new approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 13" (330 mm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Type of Gas
This dryer is equipped for use with natural gas. It is design
certified by CSA International for propane and butane gases
with appropriate conversion (Propane Kit 887168). No attempt
shall be made to convert the dryer from the gas specified
on the serial/rating plate for use with a different gas without
consulting the serving gas supplier. Conversion must be done
by a qualified service technician.
It is your responsibility to have all plumbing connections,
materials, and workmanship conform to local and state
regulations or codes of the country of destination. In the
absence of such codes, all plumbing connections, materials,
and workmanship must conform to the applicable local
requirements. In the USA this is the National Fuel Gas Code
ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian
Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or
CAN/CGAB149.2-M91 (Propane Gas) or LATEST EDITION.
It is important that gas pressure regulators meet applicable
pressure requirements, and that gas meters be rated for the
total amount of all the dryer Btu being supplied.
For ease of service, the individual gas supply line of each dryer
must have its own manual shutoff valve.
The dryer must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any
pressure test of the gas supply system at test pressures equal
to or less than 1/2 psig (3.5 kPa).
The dryer and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing
of that system at test pressures in excess of 1/2 psig (3.5 kPa).
Failure to isolate or disconnect the dryer from supply as noted
can cause irreparable damage to the gas valve, voiding the
warranty.
NOTE: Undersized gas piping will result in ignition problems,
slow drying, and increased use of energy.