Connecting 3-Wire Connection: Power Supply Cord (cont.)
2. Connect white neutral wire (white or center) (D) to center
terminal block. Tighten screw.
D
ELECTRIC DRYER ELECTRICAL CONNECTIONS (FOR U.S.A. ONLY)
Direct Wire Connection
WARNING
Use 10 gauge copper wire.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals.
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
Connection Options
Direct Wire
4-wire direct
Go to "Connecting 4-Wire Connection: Direct Wire" section.
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Fire Hazard
3. Connect remaining wires with outer terminal block screws (F).
Tighten screws. Finally, re-install terminal block cover and tighten
hold-down screw. Go to "Complete Installation" section.
3-wire direct
Go to "Connecting 3-Wire Connection: Direct Wire" section.
NOTE: If local codes do not permit connection of a cabinet-ground
conductor to neutral wire, go to "Connecting 3-Wire Connection:
Optional" section. This connection may be used with either a power
supply cord or a direct wire connection.
Remove Terminal Block Cover
C B
E
E
Before you start, disconnect power. Remove hold-down
screw (D) and terminal block cover (A).
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
D. Hold-down screw
E. Neutral ground wire
C
D
A
F
F
D
A
21