Sdu Control Panel - Volvo Penta D13 Series Operator's Manual

Hide thumbs Also See for D13 Series:
Table of Contents

Advertisement

Instruments and Controls
1
2
3
P0006710
1. Indication overspeed shutdown
2. Indication press./temp. shutdown
3. Indication broken wire shutdown
4. Buzzer
NOTICE!
The information in this section is only valid for type
approved installations.
Lamp Test
To check function of panel indications push lamp test
button (8). All indication lamps will be lit and the
buzzer will sound.
Alarms
1 The audible alarm is silenced when you
acknowledge the alarm by pressing the ACKN
button (7). The lamp (1–2) on the panel indicates
which alarm it is (also check the diode in the
shutdown unit).
2 Rectify the fault.
3 Press the reset button (SHUTDOWN RESET)
on the engine-mounted electrical box. The diode
goes out if the fault has been rectified, as does
the lamp (1–2) on the panel.
4 Start the engine.
Shutdown Override
When activated, only overspeed and broken wire
shutdowns are active.
40

SDU Control Panel

6
8
5. Key switch
6. Indication SHUTDOWN OVERRIDE
7. Acknowledge button
8. Lamp test button
NOTICE!
Check the local classification requirements to
determine when the shutdown override should be
used.
Activate SHUTDOWN OVERRIDE by turning key
switch (5) clockwise. SHUTDOWN OVERRIDE is
indicated by Lamp (6) on the panel.
IMPORTANT:
When SHUTDOWN OVERRIDE is active the engine
will not be protected by the shutdown system, this
may cause engine damage.
In Case of Emergency
In an emergency, if the shutdown unit has stopped the
engine, it is possible to run the engine despite the
activated shutdown.
1 Override the shutdown unit, refer to section
Shutdown override.
2 Push the SHUTDOWN RESET-button on the
engine-mounted electrical box.
3 Turn off the ignition.
4 Start the engine.
47708638 09-2016 © AB VOLVO PENTA