Maintenance - Volvo Penta D13 Series Operator's Manual

Hide thumbs Also See for D13 Series:
Table of Contents

Advertisement

Maintenance

This chapter contains general technical information and instructions on how the prescribed maintenance items
must be carried out. Read through the instructions carefully before starting work. The times when maintenance
items must be carried are indicated in the Maintenance Schedule, page 90.
Read through the safety precautions for maintenance and service in the Maintenance, page 92 chapter before
work on the engine is begun.
Volvo Penta recommend that all servicing with the engine running should be undertaken by an authorized Volvo
Penta workshop.
WARNING!
Care and maintenance work should be done with the engine stopped unless otherwise specified. Stop the engine
before opening or removing the engine hatch/hood. Make it impossible to start the engine by removing the start
key and cutting the system voltage with the main switches.
D13 MP with reverse gear MGX5096 A
D13 MP with reverse gear MGX5096 A
P0010476
47708638 09-2016 © AB VOLVO PENTA
1
2
1 Expansion tank
2 Coolant filler cap
3 Fuel fine filter
4 Oil filter
5 Auxiliary stop
6 By-pass filter for engine oil
7 Air filter indicator
8 Air Filter
9 Seawater Pump
10 Fuel feed pump (hand pump)
11 Heat exchanger
12 Oil dipstick, engine*
13 Oil filler cap, engine *
14 Relays
15 Alternator
*May also be located on the right side of the
engine.
1 Charge air cooler
2 Charge air cooler
3 Coolant Pump
3
91