5   Installation
5.1   Installation Instructions
Do not use near a surge voltage generated area. Solenoid lifters, high fre-
quency Induction furnaces and motors, etc. can generate high surge volt-
ages, if using near the sensor will cause the internal circuit components to
deteriorate and cause damages.
Sensors can not withstand lightning strikes. The product is CE compliant, but
can not resist surge voltage of lightning strikes, take measures to avoid
lightening strikes in the system.
Do not use in an environment where sensors could be splashed by water or
oil. Enclosure rating is IP40, please avoid water or oil splashed environment
to prevent adversely effects.
Do not use in an environment subject to large temperature cycling. Internal
components of the sensor will be affected adversely by large heating/cool-
ing cycles other than ordinary changes in temperature.
Do not mount the product in locations where it is exposed to radiant heat.
This could result in damage and/or malfunction.
Ensure the flow direction of the fluid. Follow the flow direction indicator
for installation and piping.
Flush out all dirt and dust by air blow before connect the piping to the sen-
sor.
When installation, do not drop, hit or apply excessive shock (100m/s
nal damage can cause malfunction even if the housing appears to be un-
damaged.
Do not install multiple products in close proximity. The heat generated from
each product could cause the temperature to rise and change the character-
istics of product or deterioration of the plastic parts. Please position the
products 10 mm apart from each other.
Hold the sensor body when installing. The tensile strength of the cable is
24.5 N and apply excessive pulling force can cause damage to the sensor.
NOTE
The pressure or flow rate exceeded the specified range
The sensing element may be damaged
4 Check the regulator and flow adjustment valve before introducing the fluid.
The sensing element cannot measure properly if foreign matter adheres to it.
On the inlet side, be sure to install an air filter below the filtration level of 10 µm.
EN-US · 30.30.01.02533 · 02 · 12/22