5 Installation
Recommended Equipments and Installation
Air source
Air dryer
When measuring the pressure of the inlet side, install a throttle valve or solenoid valve on
the outlet side.
When measuring the pressure of the outlet side, install a throttle valve or solenoid valve on
the inlet side.
5.2   Mounting Bracket / Optional Parts
Do not mount the sensor in a place that will be used as a foothold. The product may damage if sit or step
on it accidentally.
The LCD display may be difficult to see at certain angles.
The sensor can be installed horizontally or vertically, but the flow rates may change because of the instal-
lation way of the product or piping.
The tightening torque for screws should be under 0.5 ±0.1 Nm.
Horizontal mounting (by Through-Hole)
4 Mounting screws
20 / 46
Regulator
Micro mist
Filter
separator (oil
mist filter)
Pressure sensor
Inlet
Flow sensor
FS
EN-US · 30.30.01.02533 · 02 · 12/22
Outlet