1-16. Installation of BKDW-505/506
1-16-2. Check after Installing
Equipment
BKDW-505 (For DNW-A100/A50/A45)
Analog composite video signal generator (TEKTRONIX TSG-170A or equivalent)
Analog composite waveform/vector monitor (TEKTRONIX 1750/1780R or equivalent)
Video monitor
75 Z terminators (2 pcs)
BKDW-506 (For DNW-A100P/A50P/A45P)
Analog composite video signal generator (TEKTRONIX TSG-271A or equivalent)
Analog composite waveform/vector monitor (TEKTRONIX 1751/1781R or equivalent)
Video monitor
75 Z terminators (2 pcs)
Connection
(1) Connect the above equipments as shown below.
(2) Turn the 75Z termination switch of composite video input of the unit to ON.
Analog composite video signal generator (170A/271A)
TEST
SIGNAL
VIDEO INPUT
COMPOSITE
(75 Z ON)
1-32
BLACK
REF VIDEO
DNW
VIDEO OUTPUT
COMPOSITE 1
COMPOSITE 3
Analog composite
waveform/vector monitor (1750/1751)
EXT
75 Z
CHA
75 Z
Video monitor
(75 Z termination)
DNW-A100/A50/A45
DNW-A100P/A50P/A45P