Sony Betacam SX DNW-A100 Maintenance Manual page 257

Digital video hybrid recorder
Hide thumbs Also See for Betacam SX DNW-A100:
Table of Contents

Advertisement

6. LAU PB Level Adjustment
Measuring equipment: Audio analyzer (dBm measurement mode, 80 kHz LPF)
CH1 adjustment
(1) Connect the input of audio analyzer to AUDIO OUTPUT CH1 connector.
However, when the optional kit BKNW-105 is equipped in the DNW, connect the audio analyzer to
MONITOR OUTPUT L connector.
(2) Playback the 1 kHz, 0 VU portion (0:00 to 2:55) of alignment tape CR8-1A or CR8-1B PS, and
perform the level adjustment.
(DNW-A100/A50/A45: CR8-1A, DNW-A100P/A50P/A45P: CR8-1B PS)
Adjustment point: 1RV504/APR-12(B-1)
+4.0 ± 0.2 dBm (at 600 Z load)
Specification:
CH2 adjustment
(1) Connect the input of audio analyzer to AUDIO OUTPUT CH2 connector.
However, when the optional kit BKNW-105 is equipped in the DNW, connect the audio analyzer to
MONITOR OUTPUT R connector.
(2) Playback the 1 kHz, 0 VU portion (0:00 to 2:55) of alignment tape CR8-1A or CR8-1B PS, and
perform the level adjustment.
(DNW-A100/A50/A45: CR8-1A, DNW-A100P/A50P/A45P: CR8-1B PS)
Adjustment point: 1RV605/APR-12(F-1)
+4.0 ± 0.2 dBm (at 600 Z load)
Specification:
A
B
C
A No.
RV504
E500
RV502
TP501
TP500
RV500
S500
RV503
RV501
COR100
RV103
TP101
RV100
COR101
+4
–3
0
–20
20 18 16
RV101
RV102
E100
TP100
COR300
16 18 20
COR301
UNITY (L)
VAR (L)
COR302
+4
TP300
0
–3
>EP–GW<
–20
RV300
E300
APR-12 Board (Side A)
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
D
APR–12
E
F
G
LOTNO,
S NO,
RV605
E600
TP601
RV602
TP600
RV603
RV600
S600
RV604
RV601
COR200
RV203
TP201
RV200
COR201
+4
–3
0
–20
E200
20 18 16
RV201
RV202
TP200
TP700 TP560
COR400
16 18 20
COR401
UNITY (R)
VAR (R)
COR402
+4
TP400
0
–3
–20
RV400
E400
TP701
1
2
3
4
5
6
7
6-2. APR-12 Board Replacement
6-19