Sony Betacam SX DNW-A100 Maintenance Manual page 298

Digital video hybrid recorder
Hide thumbs Also See for Betacam SX DNW-A100:
Table of Contents

Advertisement

6-4. DM-89 Board Replacement
OXIDE Y adjustment [to step (13)]
(11) Observe the Y output signal at the component waveform monitor.
(12) Playback the multiburst signal portion (3:00 to 6:00) of the alignment tape CR5-2A or CR5-2A PS,
and adjust the level at specified frequency part by table below.
And check levels at others are within specifications.
(DNW-A100/A50/A45: CR5-2A, DNW-A100P/A50P/A45P: CR5-2A PS)
n
As the Y output is overlapped the outputs of A and B channels on the component waveform moni-
tor, adjust/check in each channel.
Adjustment points: A channel:
B channel:
Specifications (A and B channels): See the table below.
Frequency
Specification for DNW-A100/A50/A45
0.5 MHz
Reference: 100% {0 dB}
2 MHz
Adjust : 100 (104 to 95)%
1 MHz
Check : 100 (106 to 50)%
3 MHz
Check : 89 (106 to 50)%
4.1 MHz
Check : 71 (106 to 50)%
0.5
1
100%
DNW-A100/A50/A45
(13) Playback the multiburst signal portion (3:00 to 6:00) of the alignment tape CR5-2A or CR5-2A PS,
and confirm that the output level difference between A and B channels is hardly noticeable at high
frequency (4.5 MHz) part.
n
If the output level difference at 4.5 MHz part is noticeable, perform the adjustment of A34 : DM VR
3 : SUB OXIDE-A or -B. Be sure to adjust for the lower level signal only as following steps 1
through 5 on a playing back the multiburst signal portion (3:00 to 6:00) of the alignment tape.
1 To exit A32 : DM VR 1, press the MENU button once.
2 Enter A34 : DM VR 3 of the maintenance mode.
3 Change the data value of SUB OXIDE-Y-A (A channel side), and judge a lower level channel.
4 If the B channel side is lower, return the data value of SUB OXIDE-Y-A to the former data,
then adjust (add to the data value) the SUB OXIDE-Y-B until the level at 4.5 MHz of B channel
is equal to the level at 4.5 MHz of A channel.
If the A channel side is lower, adjust (add to the data value) the SUB OXIDE-Y-A until the
level at 4.5 MHz of A channel is equal to the level at 4.5 MHz of B channel.
5 To exit A34 : DM VR 3, press the MENU button once.
6-60
A32 : DM VR 1 : EQ1 OXIDE-Y-A
A32 : DM VR 1 : EQ1 OXIDE-Y-B
+0.3
{0
dB}
_0.4
+0.5
{0
dB}
_6.0
+1.5
{_1.0
dB}
_5.0
+3.5
{_3.0
dB}
_3.0
2
3 4.1
[MHz]
4.5
Frequency
Specification for DNW-A100P/A50P/A45P
2T BAR
Reference: 100% {0 dB}
3 MHz
Adjust : 89 (100 to 79)%
0.5 MHz
Check : 100 (106 to 50)% {0
1 MHz
Check : 100 (106 to 50)% {0
2 MHz
Check : 100 (106 to 50)% {0
4.1 MHz
Check : 71 (106 to 50)%
2T BAR 0.5 1
100%
DNW-A100P/A50P/A45P
{_1.0 ± 1.0 dB}
+0.5
dB}
_6.0
+0.5
dB}
_6.0
+0.5
dB}
_6.0
+3.5
{_3.0
dB}
_3.0
2
3
4.1
4.5
[MHz]
DNW-A100/A50/A45
DNW-A100P/A50P/A45P

Advertisement

Table of Contents
loading

Table of Contents