6-6. SS-63 Board Replacement

6-6-2. Error Logging Data Clear and Calendar/Clock Setting

Clear the another error logging data in NV-RAM on the SS-63 board that is installed, and set the calen-
dar/clock to the correct day and time.
Clear and set the data as follows after entering the error logger display mode.
(1) Enter the error logger display mode.
m
. There are two ways to entering the error logger display mode.
1. Press the MENU button once while pressing the ENTRY button on lower control panel.
2. Enter the maintenance mode, then enter M2 : ERROR LOGGER.
. Contents of the error logger are superimposed on the video monitor connected to the VIDEO
OUTPUT COMPOSITE 3 (SUPER) connector.
Error logging data clear [step (2)]
(2) Press the RESET button once on the lower control panel while pressing the STOP button.
Calendar/Clock setting [steps (3) through (8)]
(3) Press the SET button once on the lower control panel while pressing the STOP button.
n
After pressing the SET button once, displays the setting menu on lower half part of the superimposed
screen, and cursor (* mark) moves to the setting menu.
(4) Turn the search dial to FORWARD direction (2) until the value for year on last line (calendar and
clock) blinks.
n
The * mark is not displayed on the line of the calendar and clock.
(5) Blink the value of changing (setting) item (year, month, day, hour, minute, or second) by turning the
search dial.
(6) Change its item to a desired value by turning the search dial while pressing the JOG button on the
lower control panel.
m
. Change the value, then displays message "Push SET button".
And stops a step forward of the calendar/clock.
. If canceling that setting (return to previous value), don't press the SET button, press the MENU
button.
When pressing the MENU button once, exits the setting menu.
(7) Repeat steps (5) and (6) until changing tha all values of the requisite items.
(8) To save the setting, press the SET button once on the lower control panel.
(9) Press the MENU button once to exit the setting menu.
(10) To exit the error logger display mode, press the MENU button once again.
n
When entering the error logger display mode from the maintenance mode, returns the maintenance
mode screen. Exits the maintenance mode by pressing the MENU button once again.