Sony Betacam SX DNW-A100 Maintenance Manual page 270

Digital video hybrid recorder
Hide thumbs Also See for Betacam SX DNW-A100:
Table of Contents

Advertisement

6-4. DM-89 Board Replacement
1. Initial Data Setting
(1) Enter A3 : BETACAM PB ADJUST of the maintenance mode.
(2) Enter A30 : EQ VR.
(3) Set the specified data to all items of A30 : EQ VR.
(For setting data, refer to the table below.)
(4) To exit A30 : EQ VR, press the MENU button once.
(5) Enter A32 : DM VR 1.
(6) Set the specified data to all items of A32 : DM VR 1.
(For setting data, refer to the table below.)
(7) To exit A32 : DM VR 1, press the MENU button once.
(8) Enter A33 : DM VR 2.
(9) Set the specified data to all items of A33 : DM VR 2.
(For setting data, refer to the table below.)
(10) To exit A33 : DM VR 2, press the MENU button once.
Item of A3 :BETACAM ADJUST
A30 : EQ VR
RF GAIN METAL-Y-A
RF GAIN METAL-Y-B
RF GAIN METAL-C-A
RF GAIN METAL-C-B
RF GAIN OXIDE-Y-A
RF GAIN OXIDE-Y-B
RF GAIN OXIDE-C-A
RF GAIN OXIDE-C-B
A32 : DM VR 1
EQ1 METAL-Y-A
EQ1 METAL-Y-B
EQ1 METAL-C-A
EQ1 METAL-C-B
EQ1 OXIDE-Y-A
EQ1 OXIDE-Y-B
EQ1 OXIDE-C-A
EQ1 OXIDE-C-B
A33 : DM VR 2
MAIN METAL-Y-A
MAIN METAL-Y-B
MAIN METAL-C-A
MAIN METAL-C-B
MAIN OXIDE-Y-A
MAIN OXIDE-Y-B
MAIN OXIDE-C-A
MAIN OXIDE-C-B
6-32
Setting data for
Setting data for
DNW-A100/A50/A45
DNW-A100P/A50P/A45P
55
8E
55
8E
3F
6C
3F
6C
72
9C
72
9C
5A
81
5A
81
79
80
79
80
7C
90
7C
90
A6
A1
A6
A1
90
AD
90
AD
CD
B7
CD
B7
8E
8D
8E
8D
A6
A8
A6
A8
9E
9E
9E
9E
DNW-A100/A50/A45
DNW-A100P/A50P/A45P

Advertisement

Table of Contents
loading

Table of Contents