FortiGate-7081F System Management Module
Chassis slot number
SMM 1
SMM 2
7
5
3
1
2
4
6
8
You can use the IPMB address or chassis slot number to reference a chassis slot when entering commands in the SMM
CLI. For example, enter either of the following commands to display sensor readings for the FIM in slot 2:
sensor 0x84
sensor 2
When command syntax descriptions in this chapter include the <slot> variable you can replace it with a slot number (1 to
8) or an IPMB address number (0x82 to 0x90).
Rebooting an FIM or FPM from the SMC SDI CLI
A common use of the SMC SDI CLI is being able to remotely reboot a FIM or FPM.
From any SMC SDI CLI use the following command to reboot the FPM in slot 3:
mc reset 3 warm
Use the following command to power off the FPM in slot 4:
fru deactivate 4
Use the following command to power on the FIM in slot 2 (IPMI address 0x84):
fru activate 0x84
Comlog
All FIM and FPM SMCs include a comlog system for writing and saving console log messages. When enabled, the
comlog saves log messages in a local comlog file. Log messages include all local host console messages including
BIOS boot up messages. In the comlog these messages include the following headers:
FortiGate-7081F 7.0.5 System Guide
Name
MGMT1
MGMT2
FPM7
FPM5
FPM3
FIM1
FIM2
FPM4
FPM6
FPM8
Fortinet Technologies Inc.
IPMB Address (FRUID)
if active 0x20, if passive (the
default) 0x22
if active (the default) 0x20, if
passive 0x22
0x8E
0x8A
0x86
0x82
0x84
0x88
0x8C
0x90
54
Need help?
Do you have a question about the FortiGate-7000F Series and is the answer not in the manual?