Getting started with FortiGate-7081F
execute disk raid rebuild
The RAID is rebuilt at the current RAID level.
Use the execute disk raid status command to show RAID status.
The following command output shows the RAID status of the 4TByte SSDs configured for RAID-1.
execute disk raid status
RAID Level: Raid-1
RAID Status: OK
RAID Size: 4000GB
Disk 1: OK Used 3815GB
Disk 2: OK Used 3815GB
Resetting to factory defaults
At any time during the configuration process, if you run into problems, you can reset the FortiGate-7081F to factory
defaults and start over. From the primary FIM CLI enter:
config global
execute factoryreset
Restarting the FortiGate-7081F
To restart all of the modules in a FortiGate-7081F, connect to the primary FIM CLI and enter the execute reboot
command. When you enter this command from the primary FIM, all of the modules restart.
To restart individual FIMs or FPMs, log in to the CLI of the module to restart and run the execute reboot command.