Fig. 9: Assembling the middle tube
3. Insert the actuator into the column. With the middle tube attachment point fitted in the
middle tube adapter, turn it 90 degrees in any direction.
4. Attach at the motor end and flange end according to Chapter 6.4 and Chapter 6.5.

6.4 MOTOR SIDE INTERFACE

NOTICE
The design specifications for the top plate are available from LOGICDATA only on
request. These includes dimensions and tolerances as well as notes on material
selection and assembly.
NOTICE
Do not lift the DCDinline D by the cable and make sure that the cable is not damaged
during assembly
NOTICE
The screws and rubber disks are supplied together with the drive. The mounting
screws must be tightened to the recommended tightening torque of 2.5 - 3 Nm.
NOTICE
The DCDinline D can only be mounted once with the supplied screws, otherwise
correct tightening of the mounting screws can not be guaranteed.
NOTICE
Mounting without rubber disks is not permitted.
CAUTION
Danger due to insecure connection
To ensure a secure connection, the top plate must be designed exactly to the
specifications of LOGICDATA. Otherwise, the warranty claims are void.