Advertisement

Quick Links

DOCUMENT VERSION 0 | JANUARY 2023
DCDinline D
Manual

Advertisement

Table of Contents
loading

Summary of Contents for LOGICDATA DCDinline D

  • Page 1 DOCUMENT VERSION 0 | JANUARY 2023 DCDinline D Manual...
  • Page 2 DCDINLINE D MANUAL // PAGE 2 DCDinline D Operating Manual Document Version 0 / January 2023 This document was originally published in English. LOGICDATA Electronic & Software Entwicklungs GmbH Wirtschaftspark 18 8530 Deutschlandsberg Austria Phone: +43 (0) 3462 51 98 0...
  • Page 3: Table Of Contents

    DCDINLINE D MANUAL // PAGE 3 CONTENT Introduction Copyright Royalty-Free Use of Images and Text Trademarks Symbols and Signal Words Used Safety General Safety Regulations and Obligations Qualified Persons Liability Product Description Intended Use Delivery Scope Unpacking Assembly General Assembly 6.1.1 Actuator Dimensions...
  • Page 4 DCDINLINE D MANUAL // PAGE 4 10 Maintenance 11 Troubleshooting 12 Additional Information 12.1 Technical Specifications 12.2 Optional Products 12.3 Disposal...
  • Page 5: Introduction

    The product documentation consists of this manual and a datasheet. This document is intended to enable the assembly personnel to work safely with the DCDinline D actuator. The assembly personnel must therefore always have the complete documentation available. The document must be complete and in a perfectly legible condition.
  • Page 6: Symbols And Signal Words Used

    • Do not convert or modify the DCDinline D actuator without written approval from LOGICDATA. • In the event of malfunction or damage, the DCDinline D actuator must be replaced immediately. • Do not attempt to repair the acuator yourself.
  • Page 7: Qualified Persons

    DCDINLINE D MANUAL // PAGE 7 2.2 QUALIFIED PERSONS The DCDinline D may only be installed and commissioned by qualified persons who are authorized for instal- lation planning, installation, commissioning or maintenance/servicing and who have read and understood the DCDinline D documentation. Qualified persons have the necessary expertise to test, assess and manage...
  • Page 8: Product

    3 PRODUCT DESCRIPTION The DCDinline D is an actuator for electrically height-adjustable tables. It is installed by the customer in a column for electrically height-adjustable tables. It is controlled by a control unit from LOGICDATA, to which different hand switches can be connected. Several drives can be operated synchronously on one con- trol unit.
  • Page 9: Intended Use

    The intended use is to adjust the table height electrically. Only control units from LOGICDATA, which are parameterized for the DCDinline D, may be used for this purpose. The actuators must be assembled, commissioned and functionally checked by qualified personnel. Any other use that does not conform to the intended use will result in the loss of warranty and warranty claims.
  • Page 10: Unpacking

    6 ASSEMBLY GENERAL ASSEMBLY NOTICE Before assembly and operation, the DCDinline D must be acclimatised to the ambient conditions. NOTICE Ensure proper ESD handling throughout the installation. Errors that can be attributed...
  • Page 11: Actuator Dimensions

    DCDINLINE D MANUAL // PAGE 11 6.1.1 ACTUATOR DIMENSIONS Figure 3 shows the dimensions of the DCDinline D actuator in the retracted and extended state. Fig. 3: a: retracted length, b installation length, c extemded length 6.1.2 INSTALLATION OPTIONS The DCDinline D is designed for synchronous movement of the middle tube.
  • Page 12: Installation Tolerances

    • “Thick end down”: In this variant, the tube with the largest diameter is at the bottom (floor). The DCDinline D actuator can be used for both variants. Fig. 5: “Thick end up” (left) and “Thick end down” (right) in retracted position...
  • Page 13: Default Settings

    (see Figure 6: Symbolic image of the counterpiece for the tube adapter). NOTICE The design specifications for the customer-provided counterpiece are available from LOGICDATA only on request. These includes dimensions and tolerances as well as notes on material selection and assembly. CAUTION...
  • Page 14 2. Insert the three tubes into each other. NOTICE LOGICDATA recommends measuring the gliding properties of the height-adjustable column without the installed drive after this step. NOTICE The maximum force on the tube adapter counterpart must not exceed 150N! This is due to a difference in frictional forces be tween the tube pairs.
  • Page 15: Assembly "Thick End Down" Variant

    The middle tube adapter is produced by the customer and is fixed in the middle tube. It is connected to the drive in the installation variant “thick end down”. NOTICE The design specifications for the middle tube adapter are available from LOGICDATA only on request. These includes dimensions and tolerances as well as notes on material selection and assembly.
  • Page 16: Motor Side Interface

    These includes dimensions and tolerances as well as notes on material selection and assembly. NOTICE Do not lift the DCDinline D by the cable and make sure that the cable is not damaged during assembly NOTICE The screws and rubber disks are supplied together with the drive. The mounting screws must be tightened to the recommended tightening torque of 2.5 - 3 Nm.
  • Page 17: Flange Side Interface

    Bottom plate (developed by the customer, design specifications of LOGICDATA) Flange adjustment point NOTICE The design specifications for the bottom plate are available from LOGICDATA only on request. These includes dimensions and tolerances as well as notes on material selection and assembly.
  • Page 18: Intelligent System Protection (Isp)

    NOTICE Within a system, drives with and without ISP sensors cannot be mixed. Each drive must be of the same type. 9 DISASSEMBLY For disassembly, disconnect the DCDinline D from the power supply and proceed in reverse order to assembly.
  • Page 19 Fax: +43 (0) 3462 51 98 1030 Email: office.at@logicdata.net Always provide the product name and the revision status according to the type plate with any support re- quest. In case of a defect, replace the DCDinline D as a whole.
  • Page 20 DCDINLINE D MANUAL // PAGE 20 Possible malfunctions and their remedy: PROBLEM POSSBLE CAUSE REMEDY DCDinline D does Mains cable of the controlbox not Plug in the mains cable of controlbox not function connected DCDinline D actuator is not connected...
  • Page 21 DCDINLINE D MANUAL // PAGE 21 12 ADDITIONAL INFORMATION 12.1 TECHNICAL SPECIFICATIONS You can find the technical data of your drive in the corresponding data sheet. 12.2 OPTIONAL PRODUCTS NOTICE You can find information about available optional products in the current product catalog and at www.logicdata.net...
  • Page 22 LOGICDATA LOGICDATA North America, Inc. Electronic & Software Entwicklungs GmbH 1525 Gezon Parkway SW, Suite C Wirtschaftspark 18 Grand Rapids, MI 49512 8530 Deutschlandsberg Austria Phone: +43 (0)3462 5198 0 Phone: +1 (616) 328 8841 Fax: +43 (0)3462 5198 1030 E-mail: office.na@logicdata.net...

Table of Contents