6-5.

Service Menu

Menu Item
HOT STRT
(Only accessible in SMAW
processes)
AUTO CRTR
(Only accessible in GTAW Lift-
Arc)
HOUR MTR
OIL HOUR
OIL SET
OIL RSET
VRD
SOFT WARE
FACT RSET
OM-279836 Page 32
Complete Parts List is available at www.MillerWelds.com
Ref. 907755
Selectable Item Option(s)
LIMT OFF
LIMT 1.25
LIMT 1.50
ATCR ON
ATCR OFF
– –
– –
50 HRS
RSET YES
RSET NO
VRD ON
VRD OFF
– –
RSET YES
RSET NO
1 Adjust Control/Select Button
Press and hold control for 5 seconds, then re-
lease to access the Service Menu. Rotate the
knob to scroll through the menu items. Press
and release the control to access the options
and information within each menu item.
Rotate the control counterclockwise to de-
1
crease the value or select NO/OFF. Rotate
the control clockwise to increase the value or
select YES/ON.
Press and release control to save selection.
After 5 seconds of inactivity, the menu will
time out and the selection will not be saved.
Description
Disables Hot Start option.
Sets Hot Start current limit, selectable between 1.25 and 2.0 (0.25 in-
crements) in SMAW XX10 and SMAW Remote.
Sets Hot Start current limit, selectable between 1.5 and 3.0 (0.5 incre-
ments) in SMAW XX18.
Enables Auto Crater option.
Auto Crater gradually ramps current down after the Auto-Stop thresh-
old is met. This enables operators to better control the metal at the
end of welding and avoid the formation of an undesirable crater while
still providing shielding gas.
Disables Auto Crater option.
Displays engine hours.
Displays remaining oil change hours before service is due.
Sets the starting hours for oil change period. Selectable from 50-1500
hours in 50 hour increments.
Resets oil change period to selected value. Unit is set to factory rec-
ommended period per engine manufacturer.
Oil change remaining hours do not reset.
Enables VRD (Voltage Reducing Device) option, lowering open-cir-
cuit voltage.
Disables VRD (Voltage Reducing Device) option.
Displays the current revision of firmware installed.
Resets all settings to factory defaults.
All settings remain at previous settings.

Hide quick links: