6-5. Service Menu

.
Big Blue 800 Duo Air Pak shown.
Menu Item
HOT STRT
(Only accessible in SMAW
processes)
AUTO CRTR
(Only accessible in GTAW
processes)
VRD*
SOFT WARE
FACT RSET*
*On Side A, user must first select whether to apply settings to Side A only or to both sides.
.
Complete Parts List available at www.MillerWelds.com
Selectable Item
Option(s)
LIMT OFF
Disables Hot Start option.
LIMT 1.25
Sets Hot Start current limit, selectable between 1.25 and 2.0 (0.25 increments) in
SMAW XX10 and SMAW Remote.
LIMT 1.50
Sets Hot Start current limit, selectable between 1.5 and 3.0 (0.5 increments) in
SMAW XX18.
ATCR ON
Enables Auto Crater option.
ATCR OFF
Disables Auto Crater option.
VRD ON
Enables VRD (Voltage Reducing Device) option, lowering open-circuit voltage.
VRD OFF
Disables VRD (Voltage Reducing Device) option.
− −
Displays the current revision of firmware installed.
RSET YES
Resets all settings to factory defaults.
RSET NO
All settings remain at previous settings.
1
Press and hold control for 5 seconds,
then release to access the Service
Menu. Rotate the knob to scroll
through the menu items. Press and
release the control to access the op-
tions and information within each
1
menu item.
Rotate the control counterclockwise
to decrease the value or select NO/
OFF. Rotate the control clockwise to
increase the value or select YES/
ON.
Press and release control to save se-
lection. After 5 seconds of inactivity,
the menu will time out and the selec-
tion will not be saved.
Description
Adjust Control/Select Button
OM-279640 Page 43