6-6.

Arc Control Settings

Arc Control is not active when the Process/Contactor switch is in the following positions:
Output On: CAC-A (Air Carbon Arc Gouging)
Remote ON/OFF: GTAW (Remote TIG)
Process/Contactor Switch
Voltage sensing feeder
Complete Parts List is available at www.MillerWelds.com
Arc Control
SOFT
(–25 to –1)
� (0)
STIFF
(1 to 25)
SOFT
(–25 to –1)
� (0)
STIFF
(1 to 25)
SOFT
(–25 to –1)
� (0)
STIFF
(1 to 25)
STOP
(–5 to –1)
� (0)
STOP
(1 to 5)
STOP
(–5 to –1)
� (0)
STOP
(1 to 5)
Starting point for stainless steel wire (high inductance)
Starting point for stainless steel wire (high inductance)
Starting point for stainless steel wire (high inductance)
Starting point for aluminum wire (low inductance)
Starting point for mild steel wire
Starting point for aluminum wire (low inductance)
Starting point for aluminum wire (low inductance)
Flat or horizontal welds with XX18 electrode with short weld cables
Flat or horizontal welds with XX18 electrode with short weld cables
Starting point for aluminum wire (low inductance).
Starting point for aluminum wire (low inductance).
Flat or horizontal welds with XX18 electrode with short weld
cables
Starting point for dual shield flux core, vertical overhead
Starting point for XX18, XX13, XX14, XX24, and XX22
Starting point for dual shield flux core, vertical overhead
electrodes
Minimizes stickiness with XX18, XX13, XX14, XX24, and
XX22 electrodes. Also for pipe welding with XX10 and XX18
electrodes.
Softer, more slowly responding arc
Starting point for XX10 electrode/open root vertical down joint
Stiffer, more rapidly responding arc
Auto-Crater off. More sensitive Auto-Stop
Starting point.
Less sensitive Auto-Stop
Auto-Stop determines the arc length (voltage) threshold the
operator must exceed to terminate the arc. If arc terminates
prematurely, increase the Auto-Stop.
Auto Crater on. More sensitive Auto-Crater initiation
Starting point
Less sensitive Auto-Crater initiation
Complete Parts List is available
Complete Parts List is available
OM-279836 Page 33