Connecting To Remote Receptacle - Miller Trailblazer 325 Diesel Owner's Manual

Hide thumbs Also See for Trailblazer 325 Diesel:
Table of Contents

Advertisement

5-9.

Connecting To Remote Receptacle

A
J
K
I
B
C L N
H
M
D
G
F
E
277045-B
OM-279836 Page 10
OM-279836 Page 28
Complete Parts List is available at www.MillerWelds.com
Remote
24 Volts AC Output
(Contactor)
Remote Output
Control
A/V Amperage
Voltage
Ground
*The remaining sockets are not used.
6
12
8
13
Socket*
Socket Information
A
24 volts AC. Protected by supplementary protec-
tor CB4.
B
Contact closure to A completes 24 volt AC con-
tactor control circuit and keeps engine at Run
speed in all Wire modes..
C
+10 volts DC output to remote control.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from re-
mote control
F
Current feedback: 1 volt per 100 amperes.
H
Voltage feedback: 1 volt per 10 arc volts.
G
Circuit common for 24 volt AC circuit.
K
Chassis common.
9
7
14
10
5
11
2
4
3
1