Optional Excel Power; Simultaneous Weld And Power - Miller Trailblazer 325 Diesel Owner's Manual

Hide thumbs Also See for Trailblazer 325 Diesel:
Table of Contents

Advertisement

7-3.

Optional Excel Power

Ref. 248009 / 250717-C
7-4.

Simultaneous Weld And Power

Weld Current in Amperes
250
180
125
90
0
OM-279836 Page 42
2
Complete Parts List is available at www.MillerWelds.com
1
Total Power In Watts
2200
3500
5200
8000
12,000 (Peak)
Ref. 248009
Excel power option provides generator
power at idle speed and while welding. This
allows most job site tools to operate properly
at engine idle speed.
Use GFCI protection when operat-
ing auxiliary equipment. If unit
does not have GFCI receptacles,
use
cord. Do not use GFCI receptacles
to power life support equipment.
1 120 V 20 A AC Excel Power Receptacle
This receptacle supplies 2.4 kVA/kW of pure
120 V, 60 Hz sine wave power at ALL engine
speeds.
Circuit protection is provided by CB3 only;
CB1 does not provide protection to Excel
power.
Combined output of all receptacles limited to
peak rating of the generator.
120 V Full kVA Receptacle
Amperes
18
29
43
66
88
GFCI-protected
extension
240 V Full kVA Receptacle
Amperes
9
14
21
33
44

Hide quick links: