Service Menu - Miller Big Blue 500 Pro Owner's Manual

Hide thumbs Also See for Big Blue 500 Pro:
Table of Contents

Advertisement

6-5. Service Menu

Menu Item
HOT STRT
(Only accessible in SMAW
processes)
DIG RNGE
AUTO CRTR
(Only accessible in GTAW
processes)
VRD
SOFT WARE
FACT RSET
OM-278739 Page 34
.
Complete Parts List available at www.MillerWelds.com
Selectable Item
Option(s)
LIMT OFF
Disables Hot Start option.
LIMT 1.25
Sets Hot Start current limit, selectable between 1.25 and 2.0 (0.25 increments) in
SMAW XX10 and SMAW Remote.
LIMT 1.50
Sets Hot Start current limit, selectable between 1.5 and 3.0 (0.5 increments) in
SMAW XX18.
50 - 150
Sets current limit above preset amperage between 50 and 150 amps.
ATCR ON
Enables Auto Crater option.
ATCR OFF
Disables Auto Crater option.
VRD ON
Enables VRD (Voltage Reducing Device) option, lowering open-circuit voltage.
VRD OFF
Disables VRD (Voltage Reducing Device) option.
− −
Displays the current revision of firmware installed.
RSET YES
Resets all settings to factory defaults.
RSET NO
All settings remain at previous settings.
1
Description
1
Adjust Control/Select Button
Press and hold control for 5 seconds,
then release to access the Service
Menu. Rotate the knob to scroll
through the menu items. Press and
release the control to access the op-
tions and information within each
menu item.
Rotate the control counterclockwise
to decrease the value or select NO/
OFF. Rotate the control clockwise to
increase the value or select YES/
ON.
Press and release control to save se-
lection. After 5 seconds of inactivity,
the menu will time out and the selec-
tion will not be saved.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Big blue 600 pro

Table of Contents