Summary of Contents for Thermo Scientific Smart-Vue
Page 1
Thermo Scientific Smart-Vue Installation 316266H0 January 2011...
Page 2
Thermo Scientific products do not contain any internal components that require user intervention or repair. If the product or device shows signs of improper operation, disconnect it immediately from its power source and contact Thermo Scientific technical services so that the device can be examined under proper conditions.
Environmental protection ............2 RoHS compliance ..............2 Introduction ................3 Package contents ..............3 Product overview..............3 Main features ................3 What is a Smart-Vue wireless end-point module? .....4 Typical installation..............5 Requirements and recommendations ........6 General requirements and recommendations......6 Where to find more information..........7 Installation procedure ...............7 Getting started .................7...
Scientific products are responsible for making sure that the product is fit for the intended usage. Do not open the product casing and do not disassemble or modify internal components in any manner. Thermo Scientific products do not contain any internal components that require user intervention or repair.
Notices Conformity with This paragraph pertains to 868 MHz Smart-Vue wireless end-point modules. The CE mark on this product indicates that Thermo Fisher European regulations Scientific declares that this product is compliant with Radio equipment and Telecommunications Terminal equipment (R&TTE) directive 1999/5/EC and the Low Voltage Directive (LVD) 2006/95/EC.
Smart-Vue wireless monitoring end-point module. This manual covers Smart-Vue end-point modules for use with dry contact devices. This guide describes how to get your new Smart-Vue end-point module up and running quickly. Detailed configuration instructions and software settings are provided in the complete Thermo Scientific Smart-Vue Software User Manual provided with your product.
PC on a TCP/IP receiver installed directly on an Ethernet network. Repeaters may be used when the wireless range between the receiver and the Smart-Vue end-point module is too great to achieve a strong signal. The diagram below shows these basic configurations: Figure 2.
Smart-Vue Server/Smart-Vue Client software is installed and configured on your computer, and you have appropriate access rights to configure devices. • A Smart-Vue receiver is installed and functioning on your computer or network. General requirements • The personal computer (PC) running Smart-Vue Server software runs...
If the loop is closed, an alarm is sent. However, an alarm will not be sent if the cable between the Smart-Vue end-point module and the device is cut, as the loop will still be open just as for a “normally open”...
• Refer to the Appendix on page 18 for additional considerations. When routing the cable for any Smart-Vue sensor, avoid direct contact with or close proximity placement of the sensor cabling with any high voltage wiring. Cabling should be placed with no less than a minimum of 5 cm (2 inches) distance from high voltage components.
Installation procedure Preparing mounting kit Your Smart-Vue end-point module includes a plastic holder so you can mount the device easily on various surfaces. In addition to the provided with a magnet (optional) screws, you will also find a magnetic pad with adhesive backing that you can use to adhere the holder to metal surfaces easily.
Installation procedure Activating the end-point The Smart-Vue dry contact monitor is a standalone device that runs on battery power. To activate your Smart-Vue end-point module and add it module (automatic automatically to your wireless monitoring network, do the following: wireless setup) 1.
Page 14
Installation procedure If a receiver or repeater is within wireless range, the Smart-Vue end-point module automatically establishes the wireless connection, as shown in the sequence of screen shots below: Figure 5. Smart-Vue end-point module automatic wireless setup...
Server/Smart-Vue Client configuration. Testing the connection Checking wireless signal strength You may use Smart-Vue Client to test the wireless signal strength as described here, entering your login name and password when prompted by the software. 1. Launch Smart-Vue Client on your computer and enter your login name and password to continue.
User Manual for more details. Moving the Smart-Vue end-point module into a group 1. Launch Smart-Vue Client on your computer and enter your login name and password to continue. The new Smart-Vue end-point module should be listed as shown here, where “local” refers to the receiver and “SDP-local”...
Page 17
6. Click on Close ==> Yes ==> OK to update the end-point module, save this change, and return to the tree structure, as shown below: Figure 9. Dry contact sensor in the ““Lab_1” group Smart-Vue Dry Contact Module Installation Guide Thermo Fisher Scientific...
Page 18
2. Click on the latest reading (rectangle next to the top-most field in the image below) to read the sensor wirelessly and update the display. Figure 10. Run an on-demand read to confirm end-to-end communication Smart-Vue Dry Contact Module Installation Guide Thermo Fisher Scientific...
1 minute so you are notified as quickly as possible if the monitored device has changed from its normal state.A warning triangle is shown in the Smart-Vue display if the end-point module’s current status is in not “normal” (i.e., closed instead of open, or open instead of closed).
Page 20
3. Set the delay to wait before an alarm is sent. 4. Click on Close ==>Yes ==> OK to save your settings. Please see the Thermo Scientific Smart-Vue Software User Manual for more details on these and other important features. Click on Help ==> User Manual ( ) to open the PDF file directly.
(3.6V Lithium, 3600 mA). Contact technical support if the battery is OK and still nothing is displayed on the screen. I press the button for 3 seconds but my Smart-Vue end-point module does not connect to my receiver; what should I do? Try bringing the end-point module closer to your receiver.
Wireless end-point module operating conditions: 0°C to +50°C (+32° to +122°F); 0 to 90% RH, non-condensing • Size: 132.7 x 64.2 x 34 mm (5.2 x 2.5 x 1.3 in.) • Weight: 150 g (5.3 oz.) Smart-Vue Dry Contact Module Installation Guide Thermo Fisher Scientific...
Contact information Contact information By e-mail If you need help with your Thermo Scientific product, please send a detailed e-mail to us at the following address: E-mail: service.led@thermofisher.com Be sure to include as many details as possible, including specific product references, software versions and screen shots from your computer.
Warranty statement Warranty statement Thermo Fisher Scientific warrants the functions of the Smart-Vue Monitoring system in accordance with our standard warranty as described in the Terms and Conditions of Sale applicable to your purchase of this product. Unless otherwise agreed to in writing, Thermo Fisher Scientific warrants that the product will conform to published specifications for a period of one year from the date of delivery.