Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL 16 and is the answer not in the manual?

Questions and answers

Summary of Contents for Thermo Scientific SL 16

  • Page 1 Thermo Scientific SL 16 SL 16R Instruction manual 01 / 2020 50120986-6...
  • Page 2 © 2020 Thermo Fisher Scientific Inc. All rights reserved. BIOLiner , BIOShield , HIGHPlate , HIGHConic , AutoLock FIBERLite and CLINIConic are either registered trademarks or trademarks of Thermo Fisher Scientific. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Thermo Electron LED GmbH Zweigniederlassung Osterode Am Kalkberg...
  • Page 3 WEEE Conformity This product is subject to the regulations of the EU Waste Electrical & Electronic Equipment (WEEE) Directive 2012/19/EU. It is marked by the following symbol: Thermo Fisher Scientific has entered into agreements with recycling and disposal companies in all EU Member States for the recycling and disposal of this device.
  • Page 4: Table Of Contents

    Entering Parameters ....................4-4 Saving programs ...................... 4-6 Centrifugation ......................4-7 Temperature Adaptation during Standstill ............... 4-8 Short-term Centrifugation ..................4-8 Removing the Rotor ....................4-8 Aerosol-tight Rotors ....................4-9 Aligning the Centrifuge ................... 4-9 Thermo Scientific SL 16 / 16R...
  • Page 5 Service of Thermo Fisher Scientific ................6-5 Chapter 7 Trouble Shooting ........................7-1 Mechanical Emergency Door Release ..............7-2 Troubleshooting by User ..................7-3 When to contact Customer Service ................7-5 Chemical Compatibility Chart ................A-1 Contact Information ....................B-1 SL 16 / 16R Thermo Scientific...
  • Page 6: Preface

    • As general-purpose centrifuge, it is designed to also run other containers filled with chemicals, environmental samples and other non-human body samples. • This centrifuge should be operated by trained specialists only. Thermo Scientific SL 16 / 16R...
  • Page 7: Accident Prevention

    Preface Accident Prevention Prerequisite for the safe operation of the Thermo Scientific SL16/16R is a work environment in compliance with standards, directives and trade association safety regulations and proper instruction of the user. The safety regulations contain the following basic recommendations: •...
  • Page 8 IF A HAZARDOUS SITUATION OCCURS, TURN OFF THE POWER SUPPLY TO THE CENTRIFUGE AND LEAVE THE AREA IMMEDIATELY. Intended Use The centrifuge is to be used for separating materials of different density or particle size suspended in a liquid. Thermo Scientific SL 16 / 16R...
  • Page 9 CAUTION means that material damage could occur. WARNING means that injuries or material damage or contamination could occur. This symbol refers to biological hazards. Observe the information contained in the instruction manual to keep yourself and your environment safe. SL 16 / 16R Thermo Scientific...
  • Page 10: Introduction And Description

    Introduction and Description Contents “Characteristics” page 1-2 • • “Technical Data” page 1-3 “Directives, Standards and Guidelines” page 1-4 • • “Functions and Features” page 1-5 “Mains Supply” page 1-5 • • “Rotor Selection” page 1-6 Thermo Scientific SL 16 / 16R...
  • Page 11: Characteristics

    Introduction and Description Characteristics Characteristics The Thermo Scientific SL16/16R is an in-vitro diagnostics device according to the In-Vitro Diagnostics Directive 98/79/EC. Several rotors with a wide range of tubes can be used. The set speed is reached within seconds. The maintenance-free induction motor ensures quiet and low-vibration operation even at high speeds, and guarantees a very long lifetime.
  • Page 12: Technical Data

    Introduction and Description Technical Data Technical Data The technical data of the Thermo Scientific SL16/16R is listed in the following table. Table 1-1. Technical Data Thermo Scientific SL16/16R Feature Value Environmental conditions -Use in interior spaces -Altitudes of up to 2,000 m above sea level -max.
  • Page 13: Directives, Standards And Guidelines

    100V 50Hz IEC 61010-1 2 Edition IEC 61010-2-020 2 Edition IEC 61010-2-101 EN 61326-1 EN 61326-2-6 EN 55011A EN 61000-6-2 EN ISO 13485 SL 16 / 16R Thermo Scientific...
  • Page 14: Functions And Features

    Mains Supply The following table contains an overview of the electrical connection data for the Thermo Scientific SL16/40R. This data is to be taken into consideration when selecting the mains connection socket. Table 1-4. Electrical connection data of the Thermo Scientific SL16/40R.
  • Page 15: Rotor Selection

    Introduction and Description Rotor Selection Rotor Selection The Thermo Scientific SL16/16R is supplied without a rotor. Various rotors are available to choose from. TX-400 7500 3629 with round buckets 7500 3655 TX-200 7500 3658 with round buckets 7500 3659 BIOShield...
  • Page 16 Before use Contents “Before Setting up” page 2-2 • • “Transporting the Centrifuge” page 2-2 “Location” page 2-2 • • “Aligning the Centrifuge” page 2-3 “Mains Connection” page 2-3 • • “Storage” page 2-4 Thermo Scientific SL 16 / 16R...
  • Page 17: Chapter 2 Before Use

    People and hazardous substances must be kept out of the safety zone while centrifuging. • The supporting structure must be stable and free of resonance, for example a level laboratory bench. • The supporting structure must be suitable for horizontal setup of the centrifuge. SL 16 / 16R Thermo Scientific...
  • Page 18: Aligning The Centrifuge

    3. Check whether the cable complies with the safety standards of your country. 4. Make sure that the voltage and frequency correspond to the figures on the rating plate. 5. Establish the connection to the power supply with the connecting cable. Thermo Scientific SL 16 / 16R...
  • Page 19: Storage

    • Before storing the centrifuge and the accesories it must be cleanedand if necessary desinfected and decontaminated. • Store the centrifuge in a clean, dust-free location. • Be sure to place the centrifuge on its feet. • Avoid direct sunlight. SL 16 / 16R Thermo Scientific...
  • Page 20: Control Panel

    Control Panel Contents “Control Panel” page 3-2 • • “Keys” page 3-2 Thermo Scientific SL 16 / 16R...
  • Page 21: Keys

    Use the arrow keys in order to modify the displayed value Change Value Press the snow symbol key for prewarming or precooling the centrifuge. Snow Symbol Use the Change key to change the display mode. (Speed / RCF Value) Changing the display mode SL 16 / 16R Thermo Scientific...
  • Page 22: Operation

    • • “Saving programs” page 4-6 “Centrifugation” page 4-7 • • “Temperature Adaptation during Standstill” page 4-8 “Short-term Centrifugation” page 4-8 • • “Removing the Rotor” page 4-8 “Aligning the Centrifuge” page 4-9 • Thermo Scientific SL 16 / 16R...
  • Page 23: Switch On Centrifuge

    Note The lid should audibly click into place. Rotor Installation The approved rotors for the Thermo Scientific SL16 / 16R are listed in section “Rotor Selection” page 1-6. Use only the rotors and accessories from this list in the centrifuge.
  • Page 24 4. If available close the rotor with the rotor lid. Be sure to check all sealings before starting any aeorsol-tight applications. See the information in the rotor instruction manual. 5. Close the centrifuge lid. Thermo Scientific SL 16 / 16R...
  • Page 25: Entering Parameters

    Entering Parameters Entering Parameters The Thermo Scientific SL16 / 16R offers you a total of 9 acceleration and 10 braking curves with which samples and gradients can be centrifuged. After the centrifuge is turned on, the last running profile selected is shown.
  • Page 26 1. Press the key below the TEMPERATURE display in order to open the temperature selection menu. The display shows "Set temp": 2. Enter the desired value by pressing the key repeatedly, until the desired value shows. Thermo Scientific SL 16 / 16R...
  • Page 27: Saving Programs

    The display shows the following message: 2. Press the BUCKET key repeatedly until the bucket being used is displayed. Saving programs 1. Enter the program parameters. 2. Press any of the program store keys for 4 seconds. SL 16 / 16R Thermo Scientific...
  • Page 28: Centrifugation

    The centrifuge will be decelerated at the designated rate. The message "END" will illuminate, and after pressing the key OPEN , the lid will open and you can remove the centrifuged material. Thermo Scientific SL 16 / 16R...
  • Page 29: Temperature Adaptation During Standstill

    Short-term Centrifugation For short-term centrifuging, the Thermo Scientific SL16 / 16R has a PULSE- function. By holding down the PULSE key , spinning will start and continue until the key is let go.
  • Page 30: Aerosol-Tight Rotors

    Figure 4-2. AutoLock -lid for aerosol-tight rotors WARNING Mind the AutoLock -mandrill inside the lid. Do not touch the mandrill. Aligning the Centrifuge • To turn off the centrifuge put the mains switch to "0". Thermo Scientific SL 16 / 16R...
  • Page 31 Operation Aligning the Centrifuge 4-10 SL 16 / 16R Thermo Scientific...
  • Page 32: Chapter 5 System Menu

    Language English Deutsch Francaise End of run beep? Español Italiano Nederlands к Росс ий Keypad beep? LCD powersave? Auto lid open? 0547V01 0547V01 Software ID: 4641V05 Software NVRAM identification example values. Cycle count: 2368 Thermo Scientific SL 16 / 16R...
  • Page 33: Description

    Otherwise use the keys below the bucket selection until it says NO. Use the keys below the speed display in order to navigate through the system menu. Press the STOP key to quit the system menu. SL 16 / 16R Thermo Scientific...
  • Page 34 Cycle count Here you fine the current numbers of cycles. Use the keys below the speed display in order to navigate through the system menu. Press the STOP key to quit the system menu. Thermo Scientific SL 16 / 16R...
  • Page 35: Maintenance And Care

    Maintenance and Care Contents “Cleaning Intervalls” page 6-2 • • “Cleaning” page 6-2 “Disinfection” page 6-3 • • “Decontamination” page 6-4 “Autoclaving” page 6-5 • • “Service of Thermo Fisher Scientific” page 6-5 Thermo Scientific SL 16 / 16R...
  • Page 36: Cleaning Intervalls

    • After cleaning, treat the entire surface of aluminum parts with corrosion protection oil (7000 9824). Also treat the cavities with oil. • Store the aluminum parts at room temperature or in a cold-storage room with the cavities pointing down. SL 16 / 16R Thermo Scientific...
  • Page 37: Disinfection

    CAUTION Before using any cleaning or decontamination methods except those recommended by the manufacturer, users should check with the manufacturer that the proposed method will not damage the equipment. Observe the safety precautions and handling instructions for the cleaning agents used. Thermo Scientific SL 16 / 16R...
  • Page 38: Decontamination

    For general radioactive decontamination use a solution of equal parts of 70% ethanol, 10% SDS and water. 1. Open the centrifuge. 2. Turn off the centrifuge. 3. Pull out the power supply plug. SL 16 / 16R Thermo Scientific...
  • Page 39: Autoclaving

    The service technicians check the following: • the electrical equipment • the suitability of the set-up site • the lid lock and the safety system • the rotor • the fixation of the rotor and the drive shaft Thermo Scientific SL 16 / 16R...
  • Page 40 Thermo Fisher Scientific offers inspection and service contracts for this work. Any necessary repairs are performed for free during the warranty period and afterwards for a charge. This is only valid if the centrifuge has only been mainained by a Thermo Fisher Scientific service technician. SL 16 / 16R Thermo Scientific...
  • Page 41: Trouble Shooting

    Trouble Shooting Contents “Mechanical Emergency Door Release” page 7-2 • • “Troubleshooting by User” page 7-3 “When to contact Customer Service” page 7-5 • Thermo Scientific SL 16 / 16R...
  • Page 42: Mechanical Emergency Door Release

    4. Push the cord back into the centrifuge and mount the plug. Reconnect the centrifuge once the power has been restored. Switch on the centrifuge. Press the OPEN to have the door locks operative again. SL 16 / 16R Thermo Scientific...
  • Page 43: Troubleshooting By User

    The lid opens while the device is running. The run does not start or the centrifuge Close the lid and restart the centrifuge. runs down without being braked. If an error message appears again, inform Customer Service. Thermo Scientific SL 16 / 16R...
  • Page 44 Error during the self-test of the centrifuge program and the electronics. The run does not start or the centrifuge runs down without being braked. Restart the centrifuge. If an error message appears again, inform Customer Service. SL 16 / 16R Thermo Scientific...
  • Page 45: When To Contact Customer Service

    1. Hold down any of the keys and then switch on the centrifuge. You enter the system menu. 2. Press the START key 3. Press the key, until the following message is displayed: Software ID: XXXXXXXX 4. Communicate the software version to the service technician. Thermo Scientific SL 16 / 16R...
  • Page 46: Chemical Compatibility Chart

    S S U U S U M U S U U S U U U M U M U U U S U U S U S Benzene Benzyl Alcohol U U - M M - S U U U U U U U - M S M - Thermo Scientific SL 16 / 16R...
  • Page 47 U S U - Ethylene Dichloride Ethylene Glycol S S S S S S S S S S S S - S U S S S S S S S S M S M S SL 16 / 16R Thermo Scientific...
  • Page 48 S S S S S S Solution 555 (20%) Magnesium Chloride M S S - S S S S S S S S S S S S S S S S S S S M S S S Thermo Scientific SL 16 / 16R...
  • Page 49 S U M U U S U M S M S U U S U M M M S Phenol (5%) Phenol (50%) U S U - S U M - S U M U U U U U S U M U U S U U U M S SL 16 / 16R Thermo Scientific...
  • Page 50 S S S M S - Urea Hydrogen Peroxide (10%) U U M S S U U - S S S U S S S M U S S S S S S M S U S Thermo Scientific SL 16 / 16R...
  • Page 51 No data available. Because no organized chemical resistance data exists for materials under the stress of centrifugation, when in doubt we recommend pretesting sample lots. suggest testing, using sample to avoid loss of valuable material. Chemical resistance data is included only as a guide to product use. SL 16 / 16R Thermo Scientific...
  • Page 52: Contact Information

    France +33 2 2803 2180 +33 2 2803 2000 Italy +39 02 02 95059 341 Netherlands +31 76 571 4440 Nordic / Baltic Countries +35 89 329 100 Russia +7 (812) 703 42 15 Thermo Scientific SL 16 / 16R...
  • Page 53 +86 10 8419 3588 India +91 22 6716 2200 Japan +81 45 453 9220 Other Asian Countries +852 2885 4613 Latin America +1 866 984 3766 Other Countries +49 6184 90 6940 +33 2 2803 2180 SL 16 / 16R Thermo Scientific...
  • Page 54 Failure message ..........7-3 Features ............1-5 Safety features ..........1-2 Safety zone ............2-2 Short-term Centrifugation .......4-8 Imbalance indicator ......... 4-7 Starting centrifuge program ......4-7 Intended Use ............v Stopping the centrifugation program ....4-7 Storage ............2-4 Thermo Scientific SL 16 / 16R...
  • Page 55 Index: Switch on Centrifuge ........4-2 Technical Data ..........1-3 Temperature Adaptation .........4-8 Transporting the Centrifuge ......2-2 Trouble Shooting ..........7-1 SL 16 / 16R Thermo Scientific...

This manual is also suitable for:

Sl 16r

Table of Contents