Do Config And Manual - Danfoss AK-CC55 Water Loop User Manual

Case controller for semi plug-in
Hide thumbs Also See for AK-CC55 Water Loop:
Table of Contents

Advertisement

AK-CC55 Water Loop
Function
Values
Oil return speed
Oil return time period
Rail heat PWM - Period time
Access code 1
Display keyboard lock
0=None, 1=Local, 2=Net-
work
AO1 Min. frequency
AO1 Max. frequency
AO1 PWM frequency
AO1 Invert signal
0=No, 1=Yes
Condenser sensors
0=None, 1=S7, 2=S7 and S8
(1)
(1)
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.

DO config and manual

Table 17: DO config and manual
Function
Values
DO2 Configuration
0=None, 1=Fans, 2=Fan ECO,
3=Defrost, 4=Rail heat,
5=Alarm, 6=Light, 7=Blinds,
10=Air heater, 12=Condens-
er fan
DO3 Configuration
0=None, 1=Fans, 2=Fan ECO,
3=Defrost, 4=Rail heat,
5=Alarm, 6=Light, 7=Blinds,
10=Air heater, 12=Condens-
er fan
DO4 Configuration
0=None, 1=Fans, 2=Fan ECO,
3=Defrost, 4=Rail heat,
5=Alarm, 6=Light, 7=Blinds,
10=Air heater, 12=Condens-
er fan
DO5 Configuration
0=None, 1=Fans, 2=Fan ECO,
3=Defrost, 4=Rail heat,
5=Alarm, 6=Light, 7=Blinds,
10=Air heater, 12=Condens-
er fan
AO1 Configuration
0=None, 1=Rail heat PWM,
3=Comp. speed, 4=Brine
pump speed
Compressor 1 - override
0=MAN OFF, 1=MAN ON
Fan - override
0=MAN OFF, 1=MAN ON
Defrost A - override
0=MAN OFF, 1=MAN ON
Rail heat - override
0=MAN OFF, 1=MAN ON
Alarm relay - override
0=MAN OFF, 1=MAN ON
Light - override
0=MAN OFF, 1=MAN ON
Compressor 2 - override
0=MAN OFF, 1=MAN ON
Blinds - override
0=MAN OFF, 1=MAN ON
Air heater - override
0=MAN OFF, 1=MAN ON
Fan ECO - override
0=MAN OFF, 1=MAN ON
Rail heat PWM - override
High temperature - Priority
0=Disabled, 3=Low, 2=Medi-
um, 1=High
Low temperature - Priority
0=Disabled, 3=Low, 2=Medi-
um, 1=High
Sensor errors - Priority
0=Disabled, 3=Low, 2=Medi-
um, 1=High
DI alarms - Priority
0=Disabled, 3=Low, 2=Medi-
um, 1=High
Defrost - Priority
0=Disabled, 3=Low, 2=Medi-
um, 1=High
Miscellaneous - Priority
0=Disabled, 3=Low, 2=Medi-
um, 1=High
© Danfoss | Climate Solutions | 2022.04
R-W
Code
1
2
3
1-2
P79
1-2
P80
1-2
P82
*
*
*
1-1
P88
*
*
*
1-2
P89
*
*
*
1-3
P95
(1)
1-3
(1)
P96
1-3
P97
(1)
1-3
P98
(1)
1-3
(1)
P99
*
*
*
R-W
Code
1
2
3
1-3
q02
*
(1)
1-3
q03
*
(1)
1-3
q04
*
(1)
1-3
q05
*
(1)
1-3
q09
*
*
*
(1)
1-2
q12
*
*
*
(2)
1-2
q13
*
*
*
(2)
1-2
(2)
q14
*
*
*
1-2
q15
*
(2)
1-2
q16
*
*
*
(2)
1-2
q17
*
*
(2)
1-2
(2)
q19
*
1-2
q21
*
(2)
1-2
q23
*
(2)
1-2
q24
*
(2)
1-2
(2)
q27
*
*
*
1-2
q28
*
*
*
1-2
q29
*
*
*
1-2
q30
*
*
*
1-2
q31
*
*
*
1-2
q32
*
*
*
1-2
q33
*
*
*
4
5
6
7
8
Min.value Max.value Fact.value
*
*
P77
*
*
10 s
*
4 s
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
0 Hz
*
*
*
*
P95
*
*
*
*
100 Hz
*
*
*
*
0
*
*
*
*
*
0
4
5
6
7
8
Min.value Max.value Fact.value
*
*
*
0
*
*
*
0
*
*
0
*
*
*
0
*
0
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
0
*
*
*
0
*
*
*
0
*
*
*
0
*
0 %
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
*
*
*
*
*
0
BC378540472015en-000101 | 44
100 %
50%
600 s
60 s
60 s
10 s
999
0
2
0
P96
50Hz
500 Hz
100Hz
500 Hz
200Hz
1
0
2
1
12
5
12
1
12
6
12
3
4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
100 %
0%
3
1
3
1
3
1
3
2
3
3
3
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AK-CC55 Water Loop and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents