AK-CC55 Water Loop
Function
Description
Rail heat min. ON
Lowest permitted rail heat power. When the meas-
cycle
ured dewpoint is below the defined minimum limit
the rail heat will run with the set minimum power
Dewpoint min. limit If the measuered dewpoint is below the set value the
rail heat is running at minimum heat
Dewpoint max. limit If the measured dewpoint is above the set value the
rail heat is maximum

Light/Blinds/Cleaning control

Table 29: Light/Blinds/Cleaning control
Function
Description
Control state A
Readout of the actual control state of the controller
Night condition
Status of the day/night operation (night operation:
on/off)
Light
Actual status of output function
Blinds
Actual status of output function
Light control mode
Configuration of light function1: Light is controlled
via day/night status 2: Light is controlled via data
communication and master control parameter "MC
Light signal" 3: Light is controlled by door contact on
DI input. When the door is opened the relay will cut
in. When the door is closed again there will be a time
delay of two minutes before the light is switched off.
4: As "2" but if there are any 15-minute network errors,
the light will switch on and the night blind will open.
5: Light is controlled via DI input signal
Light at Main switch
Define how light and blinds are to be controlled at
OFF
Main switch OFF 0: Light is switched off and night
blinds are open when the main switch is off 1: Light
and night blinds are independent of main switch.
Blinds max. open
Time delay from when blinds have been opened
time
manually until they close again
Case cleaning mode The status of the function can be seen here or the
function can be started manually.0 = Normal opera-
tion (no cleaning) 1 = Only fans are running to defrost
the evaporator. All other outputs are Off. 2 = Cleaning
with stopped fans. All outputs are Off. If the function
is controlled by a digital input signal, the relevant sta-
tus can be seen here in the menu.

Display control

Table 30: Display control
Function
Description
Control state A
Readout of the actual control state of the controller
Display readout 1
Readout of the temperature shown on the display
Display air S4%
Signal to the display sensor. Here you have to define
the ratio between the sensors which the display has
to use. S3, S4 or a combination of the two. With set-
ting 0% only S3 is used. With 100% only S4 is used
© Danfoss | Climate Solutions | 2022.04
Values
Values
0=Normal ctrl., 1=Hold after defrost, 2=Min ON timer,
3=Min OFF timer, 4=Drip off, 10=Main switch OFF,
11=Thermostat cut-out, 12=Frost protection S4,
14=Defrost, 15=Fan delay, 17=Door open, 18=Melt
period, 19=Modulating temp. control, 20=Emergency
control, 25=Manual control, 29=Case cleaning,
30=Forced cooling, 32=Power-up delay, 33=Air heat-
ing, 34=Comp. safety cut-out, 45=Shut down control-
ler, 50=High S7 Brine inlet
0=OFF, 1=ON
0=OFF, 1=ON
0=OFF, 1=ON
1=Day and night, 2=Network, 3=Door switch, 4=Net-
work (Fallback), 5=Digital input
0=OFF, 1=Normal ctrl.
0=OFF, 1=Fans run, 2=Cleaning
Values
0=Normal ctrl., 1=Hold after defrost, 2=Min ON timer,
3=Min OFF timer, 4=Drip off, 10=Main switch OFF,
11=Thermostat cut-out, 12=Frost protection S4,
14=Defrost, 15=Fan delay, 17=Door open, 18=Melt
period, 19=Modulating temp. control, 20=Emergency
control, 25=Manual control, 29=Case cleaning,
30=Forced cooling, 32=Power-up delay, 33=Air heat-
ing, 34=Comp. safety cut-out, 45=Shut down control-
ler, 50=High S7 Brine inlet
Code
Short name
o88
o88 Rail Min ON%
o86
o86 DewP Min lim
o87
o87 DewP Max lim
Code
Short name
u00
u00 Ctrl. state
u13
u13 Night Cond.
u63
u63 Light relay
u82
u82 Blinds relay
o38
o38 Light config
o98
o98 Light MS=Off
P60
P60 BlindOpenTim
o46
o46 Case clean
Code
Short name
u00
u00 Ctrl. state
u56
u56 Display air
o17
o17 Disp. S4 %