Nortel LinkPlexer Installation And Configuration Manual page 152

Nortel linkplexer software: user guide
Table of Contents

Advertisement

Configuring LinkPlexer for X.25/CompuCALL
Field
IOCCCT
EQ
DLDFILE
MPCLINK table
The MPCLINK table specifies the flavor of X.25 to be used on a specific MPC
link. This table specifies the X.25 layered protocol used in the MPC to establish
and maintain links and conversions. The MPCLINK table datafill must match
the Eicon card configuration.
LINKKEY LINKALM PRTCLDAT
0 3 Y
X2584 0 0 (SVCS2WAY 20) (CLKSRCE EXTERNAL) (NODETYPE DCE)
(L3WINDOW 7)
(L3DATA P256) (THRUPUT T19200) (T2_10MS 125) $ (SVCDNA
111111111) $
152
Subfield or
Data Type/
refinement
Range
0, 4, 8, 12, 16,
20, 24, 28, 32
The PEC for
the MPC
circuit card
Alphanumeric The download file for the
Explanation and action
IOC circuit number. To
derive this value, multiply
the slot position on the IOC
shelf by four.
Equipment identifier.
FX30AA = IOM Controller
Card
load. IOM$LOAD
Standard 3.02