Configuration
Item
SwitchContinuityT
est
SwitchContinuityI
ntervalSecs
Installation and Configuration Guide
Description
If switch continuity
testing is enabled
(ON), LinkPlexer
sends a dv-Appl-
Continuity-Test to the
switch at the
configured time
interval
(SwitchContinuityInte
rvalSecs). If the
switch does not reply
to the message within
SwitchReplyTimeout
MilliSecs, the link to
the switch is dropped.
This configuration
item is only valid/read
if SwitchContinuity
Test is enabled (ON).
It specifies the
interval in seconds at
which dv-Appl-
Continuity-Test
messages are sent to
the switch.
Configuring and maintaining LinkPlexer 6.0
Rate/
Settings
Default Mandatory
ON or OFF
ON
60–86400 (1
600 (10
min to 1
min)
day)
Type
No
Static
No
Static