Replacement Of Shaft Feedthrough Seals And Valve Cleaning - VAT 613 Series Installation, Operating, & Maintenance Instructions

Butterfly pressure control valve with profibus interface vat2 profile, dn 25-320 mm, i.d. 1“ - 12", 2 sensor inputs / analog outputs / +-15v sps / pfo
Table of Contents

Advertisement

7.2.1

Replacement of shaft feedthrough seals and valve cleaning

7.2.1.1
Required tools
Allen Wrench 2 mm / 2.5mm
Allen Wrench 3 mm
Feeler gauge
1.
Vent vacuum system on both sides of the valve.
2.
Make sure the valve is in closed position
3.
Disconnect electrical POWER connector at valve and remove valve from vacuum
system.
Take care not to damage sealing surface! Do not move the plate by hands when
control and actuating unit is installed.
4.
Unfasten clamp coupling
5.
Unfasten the 2 (DN-25-50) or 4 (DN 63-320)
connection bolts and separate both parts.
Valve size DN 160 (6") and bigger require
a shortened wrench. For ordering number
refer to «Spare parts and accessories».
12 mm
6.
Unfasten screws and remove plate from
shaft.
108/129
MAINTENANCE
Clean room wipes, isopropyl alcohol
Vacuum grease
Description
Edition 11.08.2022
Series 613
Required tool
Allen Wrench:
steel coupling
2.5 mm
Allen Wrench
3 mm
Allen Wrench
3 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

613-gf series613-af series613-hf series613-cf series

Table of Contents