Peripheral Control Wiring; Input/Output Circuit Wiring - Mitsubishi Electric MDS-EX-CV Series Specifications And Instruction Manual

Table of Contents

Advertisement

MDS-EX-CV/CVH Series Specifications and Instruction Manual
6 Wiring and Connection

6.4 Peripheral Control Wiring

6.4 Peripheral Control Wiring

6.4.1 Input/Output Circuit Wiring

The CN9 connector is equipped with a 24 V input/output circuit for controlling external devices and control by external signals.
Set the relevant parameters and use them with care for the wiring since some signals are changeover type, which can be
switched over by parameters. Refer to the description of each function in the relevant sections for details on the function
specifications and settings.
Connector
Switch ON
CN24
Switch OFF
Use switches or relays for wiring that satisfy the input/output (voltage, current) conditions.
Interface name
For digital input signal (CN24)
 If a ground of the external 24 V power is same as the ground of the 24 V power in the drive unit, a fault or abnormal opera-
tion could occur.
 The maximum rising / falling edge transmission delay time is 500 μs.
IB-1501700-A
Use a minute signal switch with a stable contact and operation even at low voltage or current.
< Example > OMRON: G2A, G6B type, MY type, LY type
CN24 connector
24V
1A
Switch
4A
(1)
Input condition
18 VDC to 25.2 VDC
2.9 mA or more
4 VDC or less 1 mA or less
Selection example
6.2k
Power supply unit
30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds-ex-cvh series