Example Of Wires By Unit - Mitsubishi Electric MDS-EX-CV Series Specifications And Instruction Manual

Table of Contents

Advertisement

MDS-EX-CV/CVH Series Specifications and Instruction Manual
9 Specifications of Peripheral Devices
9.1 Selection of Wire

9.1.2 Example of Wires by Unit

The following are examples of wire selections for each unit based on the certification standards. The relation between wire
size and tolerable current conforms to the requirements specified in IEC/EN60204-1, UL61800-5-1, and JEAC8001. However,
the tolerable current is different depending on the wire specifications of each manufacturer even among the wires of the same
size.
 600 V vinyl insulated wire (IV wire) 60 °C product (Example according to IEC/EN60204-1 and UL61800-
5-1)
< MDS-EX-CV Series >
Unit Type
MDS-EX-CV-37
MDS-EX-CV-75
< MDS-EX-CVH Series >
Unit Type
MDS-EX-CVH-37
MDS-EX-CVH-75
 600 V double (heat proof) vinyl insulated wire (HIV wire) 75 °C product (Example according to IEC/
EN60204-1 and UL61800-5-1)
< MDS-EX-CV Series >
Unit Type
MDS-EX-CV-37
MDS-EX-CV-75
< MDS-EX-CVH Series >
Unit Type
MDS-EX-CVH-37
MDS-EX-CVH-75
IB-1501700-A
TE1
(L1, L2, L3)
2
AWG
mm
mm
2
14
5.5
10
TE1
(L1, L2, L3)
2
AWG
mm
mm
2
14
2
14
TE1
(L1, L2, L3)
2
AWG
mm
mm
2
14
5.5
10
TE1
(L1, L2, L3)
2
AWG
mm
mm
2
14
2
14
Terminal name
TE3
(L11, L21)
2
AWG
2
14
2
14
Terminal name
TE3
(L11, L21)
2
AWG
2
14
2
14
Terminal name
TE3
(L11, L21)
2
AWG
2
14
2
14
Terminal name
TE3
(L11, L21)
2
AWG
2
14
2
14
44
TE2
(L+, L-)
2
AWG
mm
3.5
12
8
8
TE2
(L+, L-)
2
AWG
mm
2
14
2
14
TE2
(L+, L-)
2
AWG
mm
3.5
12
5.5
10
TE2
(L+, L-)
2
AWG
mm
2
14
2
14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds-ex-cvh series

Table of Contents