MDS-EX-CV/CVH Series Specifications and Instruction Manual
14 Appx.3: EMC Installation Guidelines
14.6 EMC Countermeasure Parts

14.6.4 Surge Absorber

Insert a surge absorber in outside the AC reactor when viewed from the power supply unit and drive unit to prevent damage to
the control panel or power supply unit, etc. caused by the surge (lightning or sparks, etc.) applied on the AC power line. Do
not insert the surge absorber between the AC reactor, and the power supply unit and drive unit. Harmonic components occur
due to the power regeneration control.
Use a surge absorber that satisfies the following electrical specifications.
< Surge absorber for 200V >
RSPD Series for 200V (for both between phases and between phase and earth)
Part name
Surge withstand level 8/20 μs
RSPD-250-U4
< Surge absorber for 400V >
RSPD Series for 400V (for both between phases and between phase and earth)
Part name
RSPD-500-U4
Outline dimension drawings
Resin
Connection cable
Case
Contact: Okaya Electric Industries Co., Ltd. http://www.okayaelec.co.jp/english/index.html
Rated voltage 50/60Hz Voltage protection level Surge withstand level 8/20 μs Service temperature
3AC 250V
Rated voltage 50/60Hz Voltage protection level Surge withstand level 8/20 μs Service temperature
3AC 500V
1300V
2500A
2000V
2500A
[Unit: mm]
Circuit diagram
89
-40 to 70°C
-40 to 70°C
IB-1501700-A