5 Installation at site
5.1 Safety regulations
DANGER
WARNING
5.2 Checks to be carried out prior to installation
5.2.1 Preparing the place of pedestal mounted (stationary) installations
WARNING
Resonances
Any resonances at the usual excitation frequencies (1 x and 2 x rotational
frequency, blade passing frequency) must be prevented both in the foundation
and in the connected piping, as such frequencies may cause extreme vibrations.
Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
Delta Foul V3 Submersible Pump
Persons in the tank during pump operation
Electric shock!
Risk of injury!
Danger of death from drowning!
Never start up the pump set when there are persons in the tank.
Impermissible solid objects (tools, screws/bolts or similar) in the pump
sump/inlet tank during pump start-up
Personal injury and damage to property!
Check the pump sump/inlet tank for impermissible solid objects before flooding,
and remove, if necessary.
Installation on mounting surfaces which are unsecured and cannot support
the load
Personal injury and damage to property!
Ensure the concrete's compressive strength is sufficient (in accordance with
C35/45 in exposure class XC1 to EN 206-1).
The mounting surface must have set and must be completely horizontal and even.
Observe the weights indicated.
4 Description
Installation and operating manual
21 of 56