3.3 Storage/preservation

If commissioning is to take place some time after delivery, we recommend that
the following measures be taken for storage:
CAUTION
CAUTION
Store the pump set under dry and vibration-free conditions at a temperature above 0 °C,
in a vertical position and in its original packaging.
1. Spray-coat the inside wall of the pump casing, and in particular the impeller
clearance areas, with a preservative.
2. Spray the preservative through the suction and discharge nozzles.
It is advisable to then close the pump nozzles (e.g. with plastic caps or similar).
3. Check the power cable for damage. Attach it to the pump handle to prevent it from
trailing on the floor. Protect the cable end against moisture.
NOTE
Delta Foul V3 Submersible Pump
3 Transport/Temporary Storage/Disposal
Improper storage
Damage to the power cable!
 Support the power cables at the cable entry to prevent permanent deformation.
Damage during storage due to humidity, dirt, or vermin
Corrosion/contamination of the pump (set)!
 For outdoor storage cover the packed or unpacked pump (set) and accessories
with waterproof material.
Observe the manufacturer's instructions for application/removal of the preservative.