2.6 Safety awareness

In addition to the safety information contained in this operating manual and the
intended use, the following safety regulations shall be complied with:
• Accident prevention, health regulations and safety regulations
• Explosion protection regulations
• Safety regulations for handling hazardous substances
• Applicable standards, directives and laws
2.7 Safety information for the operator/user
• Provide the personnel with protective equipment and make sure it is used.
• Contain leakages (e.g. at the shaft seal) of hazardous fluids handled
(e.g. explosive, toxic, hot) so as to avoid any danger to persons and the
environment. Adhere to all relevant laws.
• Eliminate all electrical hazards. (In this respect refer to the applicable
national safety regulations and/or regulations issued by the local energy
supply companies.)
• If shutting down the pump does not increase potential risk, fit an
emergency-stop control device in the immediate vicinity of the pump (set)
during pump set installation.
2.8 Safety information for maintenance, inspection and
installation
• Modifications or alterations of the pump are only permitted with the
manufacturer's prior consent.
• Use only original spare parts or parts authorised by the manufacturer.
The use of other parts can invalidate any liability of the manufacturer for
resulting damage.
• The operator ensures that maintenance, inspection and installation is
performed by authorised, qualified specialist personnel who are thoroughly
familiar with the manual.
• Only carry out work on the pump (set) during standstill of the pump.
• Only perform work on the pump set when it has been disconnected from
the power supply (de-energised).
• The pump casing must have cooled down to ambient temperature.
• Pump pressure must have been released and the pump must have been
drained.
• When taking the pump set out of service always adhere to the procedure
described in the manual. (
• Decontaminate pumps which handle fluids posing a health hazard.
• As soon as the work has been completed, re-install and re-activate any
safetyrelevant devices and protective devices. Before returning the
product to service, observe all instructions on commissioning. (
6.1, Page 30)